background image

13

TC36.NG06C 050411-16

Fig. # 28

The air shutter on the burner tube controls the primary combustion air to the gas burner 
and is preset at the factory for natural gas fuel. Some adjustment may be necessary to 
obtain desired fl ame and to eliminate carbon deposits. Evaluate fl ame appearance after 
the fi replace has reached operating temperature. See Fig. #28 for proper fl ame pattern.

Open primary air shutter if the logs, glass, and fi rebox have carbon accumulation and / 
or the fl ames are long, dark and stringy. The shutter may also be opened to enhance the 
Ember Material glow and lessen the fl ame height.

Caution: Burner area may be hot!

Turn off the fi replace and allow the unit to cool before proceeding.

Caution: Proper air shutter setting is a 
must.

The fl ame should be just orange and “lazy”.  
It should NEVER be set to create sooting on 
internal parts and glass.

Burner Flame Adjustment

To Adjust: 

 (Fig. #29)

1.  Open and remove window frame and set 

aside. See "Window Frame Removal" sec-
tion found in the Installation and Operating 
Instructions manual.

2.  Remove the log set and set aside.

3.   Loosen the screw in the Primary Air 
 Shutter.

4.  Rotate the shutter to increase or decrease 

the amount of primary air.

5.  Reassemble in reverse order.

Fig. # 29

PRIMARY AIR SHUTTER

Содержание TC36 CHALET II

Страница 1: ...ns are supplementary to the Installation and Operating Instructions supplied with the fireplace and should be kept together Refer to the Installation and Operating Instructions for proper gas supply safety requirements and operating instructions TC36 CHALET II BURNER KIT INSTALLATION INSTRUCTIONS PART TC36 NG06C For use with Model TC36 Series C ...

Страница 2: ...ots in the burner overthetwoscrewslocatedinthefirebox base Fig 1 1a 2 Slide the burner back to engage the screws in the small part of the keyhole slot and tighten screws Fig 1b 3 Remove access cover from side of firebox Fig 1c Fig 1a Fig 1b SCREWS Fig 1 Fig 1c If this fireplace is to be used on Propane please convert prior to installtion See pages 9 11 ...

Страница 3: ...plate and gasket to the firebox 2 screws Attach the ignition and sensor wires to the module Red end to the connector marked by the reddot whiteendtotheconnectormarked by the white dot Fig 2 Fig 3 Fig 2 Burner Grate Installation RED END TO RED DOT WHITE END TO WHITE DOT MODULE Fig 3 ...

Страница 4: ...nd tighten Fig 4 Ensure the connections are gas tight Conceal the spark and sensor wires below the supply tubes A panel set must now be installed See InstallationandOperatingInstructions manual for details 6 Position the slots of the grate securing brackets over the holes in the floor shield and secure with the two screws Fig 5 Fig 4 ...

Страница 5: ...cover up gas lines and brackets Note Ember material placement and amount will affect flame appear ance More ember material results in lower flame height Add or remove as needed until d e s i re d flame affect Fig 6 Gas plumbing and vent connections should be completed before proceeding The logs are are fragile and should be handled with care Unpack and inspect log set There should be a total of 7 ...

Страница 6: ...6 TC36 NG06C 050411 16 Fig 9 Fig 8 LOG 2 LOG 3 ...

Страница 7: ...7 TC36 NG06C 050411 16 Fig 11 Fig 10 LOG 4 LOG 5 ...

Страница 8: ...8 TC36 NG06C 050411 16 GRATE INSTALLATION Fig 13 LOG 7 Note Improper placement of logs will cause sooting on internal parts and glass Fig 12 LOG 6 ...

Страница 9: ...mage personal injury or loss of life The qualified service agency is responsible for the proper installation of this kit The installation is not proper and complete un til the operation of the converted appliance is checked as specified in the manufacturer s instructions supplied with the kit 1 Ensure the burner pilot and gas supply are turned off and the appliance has cooled 2 Remove the two scre...

Страница 10: ... a half turn Fig 17 8 Slide the pilot adjustment band over and ensure that the hole in the orifice band is showing Fig 19 shows NG position Fig 20 shows LP position 9 Removetheminimumratescrewlocated in the valve Fig 21 Fig 20 Fig 21 Fig 17 Fig 19 10 TC36 NG06C 050411 16 M ra HOLE ...

Страница 11: ...ssure regulator Fig 23 12 Press down on the center post and rotate 90 The center post should stay down Fig 24 Replace the rubber cap 13 Fill in the date and the name of the person who performed the conversion in the white area on the conversion label Peel off the protective backing and apply the conversion label directly over the gas specifications on the rating label 14 Attach the access panel to...

Страница 12: ...ce the plug Thread sealant will be required to ensure a gas tight connection Correct gas pressure requirement Supply Pressure Natural Gas Propane For purpose of input adjustment Minimum 5 0 WC 12 5 WC Maximum 13 9 WC 13 9 WC Manifold Pressure Maximum 3 8 WC 11 0w WC Minimum 2 1 WC 5 5 WC Note To test the gas pressure turn off the gas supply before removing the plug from the supply pressure test po...

Страница 13: ...ay also be opened to enhance the Ember Material glow and lessen the flame height Caution Burner area may be hot Turn off the fireplace and allow the unit to cool before proceeding Caution Proper air shutter setting is a must The flame should be just orange and lazy It should NEVER be set to create sooting on internal parts and glass Burner Flame Adjustment To Adjust Fig 29 1 Open and remove window...

Страница 14: ...LOT SHIELD 1e TC42 NG01 BURNER WELD 1f MANIFOLD 1g 1 2 PIPE TO 1 2 TUBE CONNECTION 1h PILOT BRACKET 2a LOG 1 2b LOG 2 2c LOG 3 2d LOG 4 2e LOG 5 2f LOG 6 2g LOG 7 KIT CONTENTS 3 ORIFICE NATURAL GAS 4 PILOT ASSEMBLY 5 MAIN SUPPLY TUBE 6 PILOT TUBE 2 7 PCS LOG SET EMBER MATERIAL Not shown 2a LOG 1 2b LOG 2 2c LOG 3 2d LOG 4 2e LOG 5 2f LOG 6 2g LOG 7 3 ORIFICE NATURAL GAS 30 4 PILOT ASSEMBLY CONVERT...

Страница 15: ...15 TC36 NG06C 050411 16 ...

Страница 16: ...TECHNICAL SUPPORT 1 250 748 1184 www townandcountryfireplaces net 2975 Allenby Rd Duncan BC V9L 6V8 Printed in Canada ...

Отзывы: