T120.RHKIT   120913-28

ELECTRICAL WIRING

NOTE:  ALL ELECTRICAL WIRING MUST BE 
DONE BY A QUALIFIED ELECTRICIAN.

Consult local codes or, in the absence of 
local codes, with the current CSA C22.1 Ca-
nadian Electrical Code and in the USA with 
the National Electrical Code, ANSI/NFPA 70 
(Latest Edition).

SPEED 
CONTROL

BLOWER

120 VOLTS
60 Hz
0.7 AMPERES

G (green)

L1 (white)

L2 (black)

Fig. #10

The Optional Remote Heat blower electrical 
rating: 120V, 60HZ, 80 watts. For your protec-
tion against shock hazard, use only a properly 
grounded power supply.

This kit includes a junction box, rheostat 
and cover plate. The junction box should be 
mounted in a convenient location away from 
the fi replace.

Содержание T120.RHKIT

Страница 1: ... RHKIT 5055 T120 T120 RHKIT INSTALLATION AND OPERATING INSTRUCTIONS OPTIONAL REMOTE HEAT KIT IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER FOR WOOD FIREPLACES HEAT OUTLET DUCT REMOTE BLOWER ASSEMBLY ...

Страница 2: ...ER CASING FACE PLATE 9144 6 BLOWER FAN BRACKET 9146 7 BLOWER WALL BRACKET 9147 8 REMOTE BLOWER BOX TC36 9141 9 BLOWER 5024 65 1 2 3 4 5 6 7 8 9 11 12 13 7 10 WIRE PIG TAIL TC36 50625 11 INLET GRILL 5096 851 12 JUNCTION BOX 5024 408 13 RHEOSTAT KIT 5025 001 REMOTE BLOWER ASSEMBLY Items 5 to 10 TC36 9141 10 ITEM DESCRIPTION PART NUMBER ITEM DESCRIPTION PART NUMBER ...

Страница 3: ... kit is affected by the length and number of bends To maximize the performance the length and number of bends should be kept to a minimum ROUND DUCT 6 TYPE B MAXIMUM DUCT LENGTH OF 20 FT RECTANGULAR DUCT 10 X 3 1 4 MAXIMUM DUCT LENGTH OF 20 FT CHIMNEY INSTALLTIONS NOT SHOWN ...

Страница 4: ...emote Heat Kit you are installing REMOVE THESE KNOCKOUT PANELS AS NEEDED 2 Remove the insulation directly below the opening down to the heat shield 4 Attach the Duct Adapter Plate to top of unit using 4 screws 3 Install the Flapper Box to the top of the unit Ensure that the flap in the assembly is free to move Flap should be in the normally closed position with the blower off INSULATION REMOVED Fi...

Страница 5: ...o the Remote Blower Assembly and seal with aluminium duct tape Run a 6 diameter approved Type B venting between the blower and the fireplace Fasten in place with screws and seal with aluminium foil tape 7 Locate the make up air inlet in a desired location in the chase wall 8 Attach finishing grills over both inlet and outlet using the screws provided Fig 5 BLOWER ASSEMBLY HEAT DUCT TRANSITION BOOT...

Страница 6: ... the National Electrical Code ANSI NFPA 70 Latest Edition SPEED CONTROL BLOWER 120 VOLTS 60 Hz 0 7 AMPERES G green L1 white L2 black Fig 10 The Optional Remote Heat blower electrical rating 120V 60HZ 80 watts For your protec tion against shock hazard use only a properly grounded power supply This kit includes a junction box rheostat and cover plate The junction box should be mounted in a convenien...

Страница 7: ...e control knob clockwise until the switch clicks on Continue to rotate the knob clockwise to reduce the blower speed To turn the blower OFF rotate the control knob counter clockwise until the switch clicks off Fig 11 MAINTENANCE Town Country recommends that this kit is cleaned at least once a year It may be necessary to increase the frequency of cleaning depending on the room location type of floo...

Страница 8: ...8 T120 RHKIT 120913 28 TECHNICAL SUPPORT 1 250 748 1184 Web site www townandcountryfireplaces net 2974 Allenby Road Duncan BC Canada V9L 6V8 ...

Отзывы: