7 TC42.CE
080906-10
For reference only. Consult Manual before installation
Roof Termination Venting Charts
24” Pipe
Length Min.
NOTE: The vent must not exceed a total length of 68 feet.
Any combination of rise and run may be used but must
be constrained to the boundaries of this chart. A total of
4 90˚ elbows or combination of other elbows equalling
90˚ can be used without reducing horizontal run. For each
additional 90˚ elbow, or an equal combination of elbows,
reduce horizontal vent run by 2 feet. Ensure vent pipe is
properly supported.
** All dimensions are approximate. Both rise and run may vary with different combinations of pipe.
TCVT Roof Vent.dxf
Available on CD ROM
and www.
townandcountryfi replaces.net
**
A
Minimum rise
B
Pipe length
C
Maximum run
D
Pipe length
Maximum
74 1/4”
1-24”
29"
1-12"
78 1/2”
1-12" 1-18"
77 1/4"
1-48" 1-12"
84 1/2”
1-24" 1-12"
11' 1 1/2"
2-48" 1-24"
90 1/2”
1-24" 1-18"
15' 10"
3-48" 1-24"
1-12"
98 1/4”
1-48”
20' 10”
5-48"