RF specification data: 

 

RF Frequency: 433.92MHz 
Control method: 

1.  Send “Relay Off” command when power up 
2.  Send “Learning” command when exiting ID review/setting mode 
3.  Send “Relay On/Off” command for refreshing relay every 1 minute 
4.  Relay status is only changed in normal mode 

 

Display elements: 

 
 

 

 

Transmitter & receiver detail: 

 

Transmitter 

 

TX operating supply: 2 x AA alkaline 
Battery life: approx. 1 year 
Control range: 7 

0

C to 30 

0

Measurement range: 0 

0

C to 40

 0

C in 0.5 

0

C increments 

Temperature accuracy: +/- 1.0 

0

C @ 20 

0

 
 
 
 

Programme graphic 

Demand indicator 
(rotating) 

Weekday indicator 

Time display 

Mode indicator / 
low battery 
warning 

Override indicator /  
Programme 
number / Ambient 
temperature  

Set temperature button  

Backlight button  

Set time button  

Set programme button  

Comfort / economy button  

Reset button  

Содержание RF

Страница 1: ... boiler module RX must be installed by a qualified person We recommend that you obtain the services of a CORGI registered heating installer for any work within your boiler You can find registered installers in your area by calling 0870 401 2200 Or visit http www trustcorgi com consumers htmx Boiler module RX installation N B some boiler control panels have a hinged steel cover These are likely to ...

Страница 2: ...X are now linked 5 If the TX ID code has been left at the default value of 100 there is no need to re apply the RF linking procedure following replacement of TX batteries 6 If the TX batteries are removed or go flat and the TX is without battery power for more than 1 minute you should ensure to go through operations 1 to 3 of this sequence again to re establish the RF link which would otherwise be...

Страница 3: ...e button The pre set programme is now set for the day or day group chosen at step 2 above Set your own time programme 1 Follow steps 1 to 4 above At step 4 scroll with the up arrow button to P7 P8 or P9 These are three programme entries which are user adjustable You can apply one or all user adjustable programmes to any day or day group of your choice 2 Press the set programme button Above the P n...

Страница 4: ...tional buttons A backlight button press this once and a blue backlight will illuminate the display for 15 seconds or as long as buttons continue to be pressed and will then extinguish after a further 15 seconds Note that repeated use of the backlight facility will reduce battery life A reset button accessible only with e g a pencil or biro in the lower left corner of the keypad array Operation of ...

Страница 5: ...ter receiver detail Transmitter TX operating supply 2 x AA alkaline Battery life approx 1 year Control range 7 0 C to 30 0 C Measurement range 0 0 C to 40 0 C in 0 5 0 C increments Temperature accuracy 1 0 0 C 20 0 C Programme graphic Demand indicator rotating Weekday indicator Time display Mode indicator low battery warning Override indicator Programme number Ambient temperature Set temperature b...

Страница 6: ...ed button for ID learning Connections 1 Neutral input 2 Live input 3 Common input 4 Normally open output Applicable regulatory compliance CE directive Electromagnetic compatibility Low Voltage R TTE directive Radio and Telecommunications Terminal Equipment Battery insertion To separate the two halves of the outer housing follow the diagram below Insert the batteries into the battery compartment En...