3.
Emergency release in case of power failure
Swing gate operator SLIM S/C
Basically, the control unit can be equipped with an optional
emergency backup battery which keeps the gate operational
also in case of power failures. Should it become necessary
to disengage the operator please follow the below steps:
• Open the hexagon socket screw
(K1)
so far, that you can
open the clamping piece a bit and move out the push rod.
• Now push rod and gate are no longer connected and the
gate can be operated manually. Move the gate slowly (not
faster than in motor operation).
• To return to motor operation insert the push rod in the open-
ing of the clamping piece and tighten the hexagon socket
screw.
Before tightening please make sure, that the clamping
piece is positioned at the circular nose of the piston rod.
K