11
EN
Flow rate adjustment
38
If the flow rate is too high, then adjust the flow rate with the stop valves.
Insert a flat-head screwdriver and rotate the stop valve.
Clockwise: Flow rate decreases
Counterclockwise: Flow rate increases
Temperature control handle setting
38
Turn the temperature control handle all the way to the side where water
comes out of the shower head.
Turn the temperature control handle to the position where water at the
appropriate temperature (about 40°C) comes out, regardless of the scale.
Remove the temperature control handle.
Attach the temperature control handle at the position of the “40” mark.
After fastening the handle, check that water still comes out at the appropriate
temperature (about 40°C).
EN
Overhead shower installation
25
Attach a support to the main body.
26
Be careful that the support is not tilted and then add marking for pilot holes at
the top edge.
27
Remove the support.
28
Cover the main body to protect it from dust.
29
Open up a pilot hole at the place marked and insert a concrete plug.
30
Reattach the support to the main body.
31
Fasten the support to the wall.
32
Attach the support plate of the connecting pipe to the support.
33
Fasten the support plate and the support with screws.
34
Insert the connecting pipe into the support and fasten it with a screw.
35
Insert the overhead shower into the connecting pipe.
36
Fasten the overhead shower and the connecting pipe with a screw.
37
Install the shower head and shower hose.
*Check that there is packing inserted.
Inject some silicon between the wall and the top plate.
Water dispense checks
38
Open the stopcock and check that water comes out of the shower.
Also, check that there is no water leakage, such as from the faucet gaps or
hose connections.
Filter cleaning
39
Always clean the filters after installation.
If the filters become blocked, then the product may not function fully, such as
the flow rate may be reduced or only cold water or hot water may come out.
Also explain to the customers that they should perform cleaning from time to
time.
*When cleaning a filter, close the stopcock before removing the filter.
(For details, refer to "Daily care" in the user manual.)
Specifications
Operating pressure range
: max
1.0 MPa
: min
0.05 MPa
Recommended Operating pressure :
0.1 - 0.5 MPa
Test pressure
:
1.6 MPa
Hot water temperature
:
max. 80 °C
Recommended hot water temperature :
60 °C
Содержание TBW0541