33
34
The following phenomena may occur but they are not due to any problem.
Phenomena
Explanation
There is no high
temperature discharge
For safety reasons, even if the temperature
adjustment handle is turned fully towards the hot
water side, the structure means that only water up to
about 45°C will be discharged.
Water fl ow sounds loud
It is the sound of water fl owing when the fl ow
adjustment handle has been used to adjust the fl ow to
a small fl ow.
Before asking for repair
Phenomenon
Inspection Point
Solution
Reference
page
Only hot water
comes out
Is the stop valve on the cold
water side open enough?
Adjust the fl ow rate with
the stop valves.
Page 32
Only cold
water comes
out
Is the stop valve on the cold
water side open enough?
Adjust the fl ow rate with
the stop valves.
Page 32
Does a suffi cient amount of
hot water come from the hot-
water supply?
Check the water heating
temperature and the
operation of the water heater.
-
Temperature
cannot be
adjusted well
Does a suffi cient amount of
hot water come from the hot-
water supply?
Check the water heating
temperature and the
operation of the water heater.
-
Is the fi lter clogged?
Clean the fi lter.
Page 17
Have the stop valves on the hot and
cold water sides been adjusted?
Adjust the fl ow rate with
the stop valves.
Page 32
Has the temperature control
handle been set correctly?
Check the temperature
control handle setting.
Page 16
There is no
discharge even
if the Open/
Close button is
pressed
Is the fl ow adjustment handle
open enough?
Try turning the fl ow
adjustment handle.
Page 15
The water fl ow
is turbulent
Is the nozzle clogged?
Clean the nozzle.
Page 18
Is the fi lter clogged?
Clean the fi lter.
Page 17
Water leaks from
the connection
between the
shower hose and
the main body
Is the connection between
the shower hose and the
main body loosened?
Retighten the shower
hose.
-
The shower
head turns
naturally
Is the shower hose kinked?
Remove the kink in the
shower hose.
-
The handle
rattles
Have the set screws become
loose?
Tighten the set screws
that fasten the handle.
Page 16