6
ENGLISH
INSTALLATION PROCEDURE
Hand Shower Mount
(TBN02203/TBN02204)
1. Pass the Hand Shower Mounting
Pipe through the installation hole
from top.
3. Fasten the leader hose to the bottom opening of the diverter.
Pass the hand shower hose through the hand shower mount from
top and connect to leader hose.
Tighten with wrench.
4. Leave diverter plug in place while conducting leak testing.
Construction of access panel in surrounding tub for future service is
recommended.
2. Insert Gasket (Rubber), Washer
and mounting nut from the bottom
side.
Fixate the mounting pipe by
threading the mounting nut up the
pipe until hand tight.
Tighten the retaining screws
equally to secure.
Do not overtighten!
Mounting Pipe
for Hand Shower
Gasket
(Foam)
Gasket
(Rubber)
Washer
(Metal)
Mounting
Nut
Screw
HOT
COLD
Outlet for
Hand Shower
Leader Hose
Hand Shower Hose