background image

Water Supply

 Pressure

Minimum pressure

20 psi (0.15MPa)(flowing pressure)

125 psi (0.75MPa)(static)

Less than 185˚F (85˚C)

Water that meet National/Primary drinking water

regulation

34 - 104˚F (2

40˚C) 

1/2” NPT  

Maximum pressure

Supplied Water Temperature

Water Quality

Ambient Temperature

Water Supply Connection

Humidity

Maximum 90% RH  

2

Check local building 

code

 

Depending on the model, some specifications may differ.

● If the water supply pressure is higher than 125psi (0.86MPa), you should buy a 

   reducing valve to reduce the pressure to the range of 0.2-0.3MPa (0.2-0.3MPa). 

To use the faucet comfortably, the recommended pressure is about 30-45 psi

 (0.2-0.3MPa).

 

To prevent being scalded due to malfunction, the cold water supply pressure must 

  be higher than the hot water pressure, or you can make them equal.

 

In addition, 

  if you increase the pressure of the hot water, it still must be lower than that of cold 

  water supply side.

To prevent being scalded due to wrong operation, it is recommended the hot water

   supply temperature is 

140°F (60°C).

 

▪ Observe all local plumbing codes.

▪ Make sure water supply is shut off.

▪ Read these instructions carefully to ensure proper installation.

▪ Check to make sure you have the following parts indicated below.

For ease of water flow adjustment and inspection with tools, you should prepare an 

  extra stop valve. 

Specification

Before Installation

ENGLISH

Содержание RENESSE TSKA

Страница 1: ...ct Installation and Owner s Manual 2007 5 0GU3035 TSKA Important Safeguards 1 Specifications 2 Before Installation 2 Set up Drawing 3 Components 3 Installation Procedure 4 5 Set up Options 6 Replaceme...

Страница 2: ...e following symbols indicate safe and proper use of the product Failure to observe them may result in injury or property damage The symbols and their meanings are as follows The following table demons...

Страница 3: ...mfortably the recommended pressure is about 30 45 psi 0 2 0 3MPa To prevent being scalded due to malfunction the cold water supply pressure must be higher than the hot water pressure or you can make t...

Страница 4: ...ration depending on the model 3 Tools you will need Pipe Tape Adjustable Wrench Allen Wrech TSKA TSKD FINISHED WALL 6 5 16 160 mm 2 9 16 2 15 16 75mm MIN 3 9 16 90mm MAX HOT COLD Single Volume Conrol...

Страница 5: ...tatic Mixing valve Location of Dual Volume Control Valve Location of Single Volume Control Valve Location of HandShower Adapter FLOOR 7 7 8 200 mm Showerhead Wall Spout 1 2 pipe Single Vol Control Val...

Страница 6: ...apter Thermostatic Mixing Valve Sold separately Sold separately Sold separately Sold separately Single Vol Control Valve Connect the valves with the water supply lines Make sure that there is no leaka...

Страница 7: ...howerhead only Thermostatic Mixing Valve Trim TS170T CP Mixing Valve SMA Thermostatic TSKT Single Volume Control Trim for Head Shower TS170C CP Control Valve TSKA Dual Volume Control Trim TS170D CP Du...

Страница 8: ...free from defects in materials and workmanship for one 1 year from the date the Product is installed with all other terms of this warranty applicable except the duration of the warranty 5 THIS WARRAN...

Отзывы: