![Toto Kiwami Renesse TBKT Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/toto/kiwami-renesse-tbkt/kiwami-renesse-tbkt_installation-and-owners-manual_1139638004.webp)
4
ENGLISH
FIN
IS
HE
D
W
AL
L
RIM WIDTH (TUB)
WATER SUPPLY LINE
distance between TUB edge
and valve
Less than 7-7/8” (200mm)
minimum distance
2-3/8” (60mm)
Hole Diameter
1-3/4” (44 mm) MIN.
1-13/16” (46 mm) MAX.
1. Before installation, the
water pipes must be
completely flushed of dirt
and debris.
2. Drill holes as specified
in the illustration to the
right. Make sure the
rough deck and selected
finished deck materials
meet the following
specifications:
Rough Deck
Thickness
Finished Deck
Thickness
Min
Max
Min
Max
9/16”
(15 mm)
1-1/4”
(32 mm)
1/2”
(13 mm)
3/4”
(19 mm)
CAUTION
The bath basin must be
parallel to the center line of
the faucet installation hole.
Bath basin side
Center line
3-15/16”
(100 mm)
3-15/16”
(100 mm)
Hole Diameter
1-5/8” (42 mm) MIN.
1-3/4” (44 mm) MAX.
Hole Diameter
1-3/4” (44 mm) MIN.
1-13/16” (46 mm) MAX.
insTallaTion PRoCeDURe