>
TEMPERATURE CALIBRATION TABLE
•
Firstly, determine with a calibrated thermometer the temperature difference –
then use the following table to adjust your thermostat.
Thermostat
Fahrenheit Celsius
Calibration Number
Change
Change
+3.0
+6F
+3.0C
+2.5
+5F
+2.5C
+2.0
+4F
+2.0C
+1.5
+3F
+1.5C
+1.0
+2F
+1.0C
+0.5
+1F
+ .5C
Factory Setting
00
No Correction Required
-0.5
-1F
-.5C
-1.0
-2F
-1C
-1.5
-3F
-1.5C
-2.0
-4 F
-2.0C
-2.5
-5F
-2.5C
-3.0
-6F
-3.0C
ADVANCED SETTINGS – CALIBRATION
37
>
CALIBRATION OF TEMPERATURE
Your TotalTouch™ Thermostat is rated for an accuracy of +/-1 degree with
temperature
•
If you have determined due to drafts, sunlight or other environmental factors that
your thermostat needs calibration, follow this easy guide. Common causes of off-
set are lack of air circulation in the vicinity of your TotalTouch™ unit or skylights.
ADVANCED SETTINGS – CALIBRATION
36