TOTALINE Gold P274-1100 Скачать руководство пользователя страница 7

7

Fig. 14 — Single-Speed Packaged Heat Pump with 

2-Stage Electric Heat — Model 1200 Thermostat

Fig. 15 — Single-Speed Packaged Heat Pump with 

Single-Stage Gas Furnace — 

Model 1200 Thermostat

Fig. 16 — Two-Speed Air Conditioner with 

Single-Stage Furnace — Model 1300 Thermostat

Fig. 17 — Two-Speed Air Conditioner with 2-Stage 

or Variable-Speed Furnace — 

Model 1300 Thermostat

R

G

Y/Y2

Y1/W2

B

S

1

S

2

MODEL 1200

THERMO

S

TAT

S

PLICE

BOX

VIO

ORN

WHT

RED (TRAN)

BRN

WHT

BRN

C

O/W2

W/W1

24 VAC COMM

N/A

OUTDOOR

S

EN

S

OR

CONNECTION

HEATER

CONTROL BOX

YEL

GRN

RED

RED

PNK

HEAT 

S

TAGE 2

COOL/HEAT

S

TAGE 1

RV

S

 COOLING

N/A

FAN

24 VAC HOT

S

UGGE

S

TED DIP 

S

WITCH 

S

ETTING

S

ON

A

B

C

D

OFF OFF OFF OFF

See Notes 3, 9, and 10 on page 9.

R

G

W/W1

Y/Y2

B

S

1

S

2

MODEL 1200

THERMO

S

TAT

S

PLICE

BOX

YEL

ORN

BRN

C

O/W2

Y1/W2

24 VAC COMM

N/A

OUTDOOR

S

EN

S

OR

CONNECTION

WHT

GRN

RED

COOL/HEAT

S

TAGE 1

HEAT 

S

TAGE 2

RV

S

 COOLING

N/A

FAN

24 VAC HOT

S

UGGE

S

TED DIP 

S

WITCH 

S

ETTING

S

ON

A

B

C

D

OFF OFF OFF OFF

See Notes 3, 9, and 10 on page 9.

COOL 

S

TAGE 1

FAN

HEAT 

S

TAGE 1

COOL 

S

TAGE 2

N/A

24 VAC HOT

R

W/W1

Y/Y2

O/W2

Y1/W2

G

24 VAC COMM

N/A

OUTDOOR

S

EN

S

OR

CONNECTION

C

B

S

1

S

2

C

Y2

C

MODEL 1

3

00

THERMO

S

TAT

S

INGLE-

S

TAGE

FURNACE

TWO-

S

PEED

AIR CONDITIONER

W

R

Y1

R

G

Y

S

UGGE

S

TED DIP 

S

WITCH 

S

ETTING

S

ON

A

B

C

D

OFF OFF

ON OFF

See Note 2 on page 9.

COOL 

S

TAGE 1

FAN

HEAT 

S

TAGE 1

COOL 

S

TAGE 2

HEAT 

S

TAGE 2

24 VAC HOT

R

W/W1

Y/Y2

O/W2

Y1/W2

G

24 VAC COMM

N/A

OUTDOOR

S

EN

S

OR

CONNECTION

C

B

S

1

S

2

C

Y2

C

MODEL 1

3

00

THERMO

S

TAT

TWO-

S

TAGE OR

VARIABLE-

S

PEED

FURNACE

TWO-

S

PEED

AIR CONDITIONER

R

Y1

R

G

W/W1

HUM

Y/Y2

W2

Y1 *

S

UGGE

S

TED DIP 

S

WITCH 

S

ETTING

S

ON

A

B

C

D

OFF OFF ON OFF

See Notes 2 and 5 on page 9.

*

 May not be present on equipment.

Содержание Gold P274-1100

Страница 1: ...evere personal injury or death WARNING signifies a haz ard which could result in personal injury or death CAUTION is used to identify unsafe practices which would result in minor personal injury or property damage GENERAL Totaline 7 day programmablethermostatsarewall mount ed low voltage thermostats which maintain room temperature by controlling the operation of an HVAC heating ventilation and air...

Страница 2: ...default ON Normal recovery HP AC SELECT SWITCH C Active on 1200 and 1300 Models Only Use Switch C to select between AC and HP installations The 1200 and 1300 models have an extra relay to control the HP reversing valve When a 1200 model thermostat is placed in AC mode this extra relay is converted to a second stage heat output This allows thermostat control of 2 stage fur naces or 2 stage strip he...

Страница 3: ... pump HS Intelligent heat staging with a variable speed fan coil and 1 speed heat pump Table 1 Model No and Proper Wiring for Intended Applications LEGEND Terminals S2 and C are internally connected Do not ground shield to terminal C of thermostat Be careful not to drill into wiring in the wall Electrical shock could result Improper wiring or installation may cause damage to the thermostat Check t...

Страница 4: ...W2 Y1 W2 R G 24 VAC COMM N A OUTDOOR SENSOR CONNECTION C B S1 S2 C Y C MODEL 1100 THERMOSTAT TWO STAGE OR VARIABLE SPEED FURNACE SINGLE SPEED AIR CONDITIONER W W1 Y Y2 HUM W2 SUGGESTED DIP SWITCH SETTINGS ON A B C D OFF OFF OFF OFF See Notes 1 and 6 on page 9 24 VAC HOT FAN COOL STAGE 1 HEAT STAGE 1 N A N A R G W W1 Y Y2 O W2 Y1 W2 R G 24 VAC COMM N A OUTDOOR SENSOR CONNECTION C B S1 S2 C Y C MODE...

Страница 5: ... Y Y2 O W2 B S1 S2 MODEL 1100 THERMOSTAT SPLICE BOX GRN WHT BRN WHT BRN C Y1 W2 24 VAC COMM N A OUTDOOR SENSOR CONNECTION HEATER CONTROL BOX RED YEL SUGGESTED DIP SWITCH SETTINGS ON A B C D OFF OFF OFF OFF See Notes 1 9 and 10 on page 9 24 VAC HOT FAN HEAT STAGE 1 COOL STAGE 1 HEAT STAGE 2 N A R G W W1 Y Y2 O W2 Y1 W2 R G 24 VAC COMM N A OUTDOOR SENSOR CONNECTION C B S1 S2 C Y C MODEL 1200 THERMOS...

Страница 6: ... N A R G R G 24 VAC COMM N A OUTDOOR SENSOR CONNECTION C B S1 S2 C C MODEL 1200 THERMOSTAT EASY SELECT TERMINAL BOARD J1 JUMPER REMOVE J2 JUMPER FOR HEAT STAGING SINGLE SPEED AIR CONDITIONER DH O Y1 Y Y2 Y Y Y2 O W2 Y1 W2 W W1 W1 W2 SUGGESTED DIP SWITCH SETTINGS ON A B C D OFF OFF ON OFF See Notes 2 and 7 on page 9 COOL STAGE 1 FAN HEAT STAGE 1 N A HEAT STAGE 2 24 VAC HOT R G W W1 Y1 W2 O W2 B S1 ...

Страница 7: ...MOSTAT SPLICE BOX YEL ORN BRN C O W2 Y1 W2 24 VAC COMM N A OUTDOOR SENSOR CONNECTION WHT GRN RED COOL HEAT STAGE 1 HEAT STAGE 2 RVS COOLING N A FAN 24 VAC HOT SUGGESTED DIP SWITCH SETTINGS ON A B C D OFF OFF OFF OFF See Notes 3 9 and 10 on page 9 COOL STAGE 1 FAN HEAT STAGE 1 COOL STAGE 2 N A 24 VAC HOT R W W1 Y Y2 O W2 Y1 W2 G 24 VAC COMM N A OUTDOOR SENSOR CONNECTION C B S1 S2 C Y2 C MODEL 1300 ...

Страница 8: ...A OUTDOOR SENSOR CONNECTION C B S1 S2 C Y Y2 C W2 MODEL 1300 THERMOSTAT SINGLE STAGE FURNACE TWO SPEED HEAT PUMP R Y1 O R W3 G W SUGGESTED DIP SWITCH SETTINGS ON A B C D OFF OFF OFF OFF See Notes 3 8 and 9 on page 9 COOL HEAT STAGE 1 RVS COOLING HEAT STAGE 3 COOL HEAT STAGE 2 FAN 24 VAC HOT R W W1 Y Y2 O W2 Y1 W2 G 24 VAC COMM N A OUTDOOR SENSOR CONNECTION C B S1 S2 C Y2 C W2 MODEL 1300 THERMOSTAT...

Страница 9: ...at operation via furnace control algorithm Refer to indoor equipment installation instructions for proper setup 7 Refer to fan coil installation instructions for proper wiring 8 Select the ZONE position on the 2 speed heat pump control board 9 Refer to outdoor equipment installation instructions for proper setup 10 Program thermostat to bring on fan G with any heat W selec tion See Step 5 Set Ther...

Страница 10: ...gu ration value larger on the left of the thermostat display will flash Change the configuration value with the Up and Down Arrow buttons Press the Set Time Temp button again to save the configuration and change a different configuration Record all chosen configuration options on page 16 Press the End but ton to exit Configuration mode The thermostat will automati cally exit Configuration mode if ...

Страница 11: ...K RED RED RED BLK BLK SENSOR 8 SENSOR 9 SENSOR 5 RED BLK SENSOR 6 SENSOR 7 BLK RED LEGEND TB Terminal Block Factory Wiring Field Wiring TB S1 S2 TO THERMOSTAT RED BLK RED RED BLK BLK BLK RED BLK RED SENSOR 1 SENSOR 2 SENSOR 3 SENSOR 4 SPACE TEMPERATURE AVERAGING 4 SENSOR APPLICATION SPACE TEMPERATURE AVERAGING 9 SENSOR APPLICATION ...

Страница 12: ...just the offset or until the thermostat temperature matches room temperature ENABLE AUTO MODE Option No 15 The enable au to mode selection allows the installer to enable or disable AUTO mode automatic changeover between heat and cool When disabled AUTO indicator does not appear when succes sive presses of the Mode button are used to move between OFF HEAT COOL and E HEAT in heat pump systems Factor...

Страница 13: ...to 4 time periods WAKE DAY EVE SLEEP Each time period has a start time heating set point and cooling set point Fill in the schedule table on page 16 as an aid to programming the daily schedules PROGRAMMING MODE To program the daily schedules perform the following procedure 1 Enter Programming mode by pressing the Program button The PROGRAMMING indicator will appear on the thermostat display The cu...

Страница 14: ...the Fan and Up Ar row buttons together increase temperature Fifteen Minute Cycle Timer This timer prevents the start of a heating or cooling cycle until at least 15 minutes after the last start of the same cycle Its function is to assure that equipment is not cycled more than 4 times per hour This timer is defeated for 1 cycle when the desired temperature is manual ly changed It can also be defeat...

Страница 15: ...at should be replaced E2 on temperature display Brownout condition or too low of voltage to thermostat Double check wiring and check for 24 vac between R and C E2 will clear 15 seconds after proper voltage is restored E3 on temperature display Outdoor temperature reading out of range and needed for Option No 8 Check out door temperature sensor and its wiring Clean Filter on temperature display Aft...

Страница 16: ...t Recovery OFF enable ON disable Switch C Heat Pump Operation OFF enable ON disable Switch D Intelligent Heat Staging OFF disable ON enable 01 Anticipator Adjustment 1 9 factory default 3 02 Clean Filter Timer Adjustment OF or 1 9 factory default 2 03 Farenheit or Celsius Operation F or C factory default F 04 Enable Fan G On with Any Heat W OF or On factory default OF 05 07 N A 08 Auxiliary Heat L...

Отзывы: