P340 Series
570-219
3
69-2268—03
M29128
–+ –+
– +
For 24VAC primary power, connect common
side of transformer to “C” terminal.
Insert supplied batteries for
primary or backup power.
Power options
Push excess wire back into the wall opening. Plug
wall opening with non-flammable insulation.
Remove factory-installed jumper
only for two-transformer systems.
Conventional Terminal Letters:
R
Heating power. Connect to secondary side of
heating system transformer.
Rc
Cooling power. Connect to secondary
side of cooling system transformer.
C
Common wire from secondary side of
cooling transformer (if 2 transformers).
W
1st stage heat relay.
W2
2nd stage heat relay.
Y
1st stage compressor contactor.
Y2
2nd stage compressor contactor.
G
Fan relay.
S1
Optional outdoor or remote sensor.
S2
Optional outdoor or remote sensor.
Heat Pump Terminal Letters:
R
Heating power. Connect to secondary
side of heating system transformer.
Rc
Cooling power. Connect to secondary
side of cooling system transformer.
C
Common wire from secondary side of
cooling system transformer.
Y
1st stage compressor contactor.
Y2
2nd stage compressor contactor.
Aux
Auxiliary heat relay.
G
Fan relay.
E
Emergency heat relay.
L
Heat pump reset (powered continuously
when System is set to Em Heat; system
monitor when set to Heat, Cool or Off).
O/B
Changeover valve for heat pumps.
S1
Optional outdoor or remote sensor.
S2
Optional outdoor or remote sensor.
Terminal Designations
Shaded areas below apply only to
P340-1320
.
M28654
Wiring
M28653
M28655