2.3.5 Batch number clearance
Press CLEAR key to clear the preset batch number on the
batch/parameter. And the machine withdraws from the batching state.
2.4 Setting the auxiliary functions
Press “7777”, i.e. “7” for four times, to change the parameters of the
machines, and the batch/parameter display will show “SEt”:
2.4.1 Press “1” to enter the setting of UV detection
The sensitivity of UV detection is adjustable by continuously pressing the
“1” key, and the sensitivity will be changed from SU1 to SU15, (the
default setting is SU7). The smaller the number follows SU, the higher the
sensitivity of UV detection.
2.4.2 Press “2” to enter the setting of Magnetic detection
The sensitivity of Magnetic detection is adjustable by continuously
pressing the “2” key, and the sensitivity can be changed from Sd1 to
Sd15 (the default setting is Sd7). The smaller the number follow Sd, the
higher the sensitivity of Magnetic detection.
2.4.3 Press “3” to enter the setting of width difference of the banknotes
The sensitivity of width difference detection is adjustable by continuously
pressing the “4” key, and the sensitivity will be changed from dd1, dd2,
dd3, dd4, dd5, dd6 and dd7 (the default setting is dd4). When the width
difference between the bills is detected to be over the set parameter, the
machine alarms and stops counting.
2.4.4 Press “4” to enter the setting of banknotes density
The sensitivity of banknote density is adjustable by continuously pressing
the “4” key, and the sensitivity will be changed from dE1, dE2, dEN3, dE4,
dE5, dE6 and dE7 (the default setting is dEN4).
Please note:
For the sensitivity of counterfeit detection, the smaller the
number, the higher the sensitivity.
If mis-alarm frequently occurred, please decrease the sensitivity of
counterfeit detection, i.e. increase the number; if the machine