     MAINTENANCE INSTRUCTIONS 
      HALON 1 / 1,2 / 2,5 AIR TOTAL 

ATA 26-24-05   

 

 

 

 

                                       I 74/76-00 dated May 2014 

        Page 5 of 13 

Subject to change without notice  

   

 

               Replaces H 74/76-00 dated October 2012 

Release: Operating instructions: August 2003 
               Technical data: January 2005 

Operating instructions 

 

When held in place with a strap, open fastener and remove extinguisher from bracket. Bent  
down safety lever (black), remove seal wire and than squeeze release lever (red). Attack fire with 
the discharging extinguishing agent. 
 
Attack the fire starting from front. Discharge agent in shots according to requirements. 

 
 
 

Technical data

 

 
 

Part. No. 

Dimensions 

 
 
  Height         Dia. 

Weight w/o      
bracket and  
fastening strap 
  Kg         Lbs 

Weight bracket 
and fastening 
strap approx. 
  Kg         Lbs 

Nominal 
pressure 
by 15

C/ 

     59

Container 
test 
press. 

Filling 

 
 
 Kg     Lbs 

Discharge 
time  
approx. 

Heights 

 
74-00 

265mm 
10.4 in. 

82mm 
3.2in. 

 
1.99 

 
4.39 

 
0.21 

 
0.46 

11 bar 
156.5 psi 

30 bar 
427 psi 

 

 
2.2 

 
7 sec 

20.000m 
65.616 ft. 

 
74-20 

265mm 
10.4 in. 

82mm 
3.2in. 

 
2.19 

 
4.83 

 
0.21 

 
0.46 

11 bar 
156.5 psi 

30 bar 
427 psi 

 
1.2 

 
2.65 

 
9 sec 

20.000m 
65.616 ft. 

 
74-21 

265mm 
10.4 in. 

82mm 
3.2in. 

 
2.19 

 
4.83 

 
0.5 

 
1.10 

11 bar 
156.5 psi 

30 bar 
427 psi 

 
1.2 

 
2.65 

 
9 sec 

20.000m 
65.616 ft. 

 
76-00 

380mm 
15 in. 

100mm 
4in. 

 
4.02 

 
8.86 

 
0.41 

 
0.90 

11 bar 
156.5 psi 

30 bar 
427 psi 

 
2.5 

 
5.51 

 
10 sec 

20.000m 
65.616 ft. 

 

 

for exact weight see the check note label on the extinguishers backside. 

 
 
(1)   Operating temperature range 
 

 

All fire extinguishers can be operated at temperatures of between -40°C and +70°C 

 

(-40°F and +158°F). 

 

(2)   Throw distance 

 

 

 

 

Throw distance for the extinguishers 74-00, 74-20, 74-21 and 76-00 is 3.50 m  

 

(11.5 Ft) at +20°C (+68°F).

 

 

 
 
 
 
 
 
 
 
 
 

Содержание 74-00

Страница 1: ...d October 2012 Release January 2005 MAINTENANCE INSTRUCTIONS WITH ILLUSTRATED PARTS LIST HALON 1 1 2 2 5 AIR TOTAL List of Portable Fire Extinguishers Part No Type 74 00 HAL 1 0 74 20 HAL 1 2 74 21 HA...

Страница 2: ...A 26 24 05 I 74 76 00 dated May 2014 Page 2 of 13 Subject to change without notice Replaces H 74 76 00 dated October 2012 Release August 2003 Inspection Record Inspec No Date issued Performed date Ins...

Страница 3: ...spection record sheet 2 August 2003 Table of contents 3 May 2014 Description 4 August 2003 Operating instructions 5 August 2003 Technical data 5 January 2005 Inspection regulations 6 October 2012 Disa...

Страница 4: ...flammable liquids flammable gases and for fires in the presents of electrical tensions up to 1000 Volt The extinguishers are designed for a one hand operation 2 Range of application a Fire Class ABC...

Страница 5: ...ning strap approx Kg Lbs Nominal pressure by 15 C 59 F Container test press Filling Kg Lbs Discharge time approx Heights 74 00 265mm 10 4 in 82mm 3 2in 1 99 4 39 0 21 0 46 11 bar 156 5 psi 30 bar 427...

Страница 6: ...section of the dial Weight control scale Permissible deviation 2 of fill capacity year but not more than 10 of fill capacity 3 Characteristics after 5 years After expiration of 5 years in case of fill...

Страница 7: ...wrench size 17 Unscrew the siphon tube 220 220A Visually inspect valve and container threads and O ring seat for damage Press operation lever and check mobility of valve spindle Visually inspect insid...

Страница 8: ...lamp The weight of this clamp must be taken into consideration in the weighing process The extinguishing agent is filled according to weight Care must be taken to observe the permissible fill toleranc...

Страница 9: ...to determine the total weight This weight must be entered in the inspection record card and on the extinguisher check note when weighing the extinguisher the weight of seal seal wire and the approval...

Страница 10: ...76 00 dated October 2012 Release May 2014 Illustration 2 Filling Station Schematic arrangement Storage The storage temperature shall not exceed 70 C 158 F Ambient air should be dry and free of corros...

Страница 11: ...mber shown on illustration 3 A stroke in front of the item number indicates that this part is not shown on the illustration 2 Part number Manufacturers original part number 3 Ident number Manufactures...

Страница 12: ...0A 0074 47 0255479 Protective foil 1 50 0074 U12 0621087 Valve assembly HAL 1 1 2 A B 1 50A 0076 U04 0621303 Valve assembly HAL 2 5 C 1 60 E000 11936 220295 Copper seal wire A B C 1 70 E000 00101 1200...

Страница 13: ...MAINTENANCE INSTRUCTIONS HALON 1 1 2 2 5 AIR TOTAL ATA 26 24 05 I 74 76 00 dated May 2014 Page 13 of 13 Subject to change without notice Replaces H 74 76 00 dated October 2012 Release August 2003...

Отзывы:

Похожие инструкции для 74-00