4. 

Installation 

4.1. 

Safety Information 

Always follow basic safety precautions when installing Total Recall VR to reduce the 
risk of injury from electrical shock and fire. 

 

 

 

WARNING: Potential shock hazard. Total Recall VR must be 
installed by qualified person. 

 

 

Observer the following: 

1.

 

Read and understand all instructions in Total Recall VR guides. 

2.

 

Observe all warnings and instructions marked on the product. 

3.

 

Use only grounded electrical outlet when connecting Total Recall VR to a power 
source. If you are unsure the outlet is grounded, then have a qualified electrician 
check it. 

4.

 

First connect Total Recall VR to grounded outlet, and only then connect the 
appropriate interface lines. 

5.

 

Do not touch the contacts on the ends of any cables used with Total Recall VR. If 
any cable becomes damaged, then have it replaced immediately. 

6.

 

Shut down and unplug Total Recall VR from telephone jacks, and then from power 
outlets, prior to moving or cleaning. 

7.

 

Do not open Total Recall VR. There are no user serviceable parts inside Total 
Recall VR. Refer all servicing to qualified personnel. 

 

4.2. 

General 

Total Recall VR is computer equipment and in general has the same physical and 
electrical requirements as desktop PCs. Attention should be paid to their environment to 
assure long life and reliable operation. 

4.3. 

Location 

When choosing a location for your Total Recall VR, consider the following: 

 

Convenience

. Make the unit accessible to operators and service personnel who 

need to access the embedded display and control keypad. 

 

Security

. User with access to the unit can remove power, disconnect other 

cables, monitor and play recordings, create archives and possibly compromise 
the recordings on Total Recall VR in other ways. Logins are no protection 
against determined attackers with physical access to the unit. 

Содержание Classic Desktop

Страница 1: ...0 In accordance with CC BY SA if you distribute this document or an adaptation of it you must provide the URL for the original version Prolancer as the licensor of this document waives the right to e...

Страница 2: ...ty Ltd Prolancer web site Available from http www prolancer com au 3 Prolancer Pty Ltd Total Recall VR Overview User Guide 7 0 April 2014 4 Prolancer Pty Ltd Total Recall VR Deployment User Guide 7 0...

Страница 3: ...our LCD Screen 10 3 5 Control Keypad 11 4 Installation 13 4 1 Safety Information 13 4 2 General 13 4 3 Location 13 4 4 AC Power 14 4 5 Local Area Network 14 4 6 Analogue Signal Sources 14 4 7 VoIP Net...

Страница 4: ...ecall VR Classic Desktop Page 4 of 32 7 Preventative Maintenance 30 7 1 Air Filter 30 7 2 Hard Disks 30 7 3 Disk Space 31 7 4 Orderly Shutdown 31 8 Troubleshooting 32 8 1 Support Information 32 8 2 Fo...

Страница 5: ...ession or services that need restarting before an update will apply Ignoring the information will not cause data loss but may cause irritation and frustration Warnings should not be ignored Ignoring w...

Страница 6: ...d 1 1 3 Procedures We use numbered sequence of steps to define procedures for performing certain tasks For example Procedure Title 1 This is the first step of the procedure 2 This is the second step o...

Страница 7: ...create electronic records of many forms of audio communication including telephone 2 way radio broadcast radio public address room microphones and much more 2 2 About This Guide This guide contains in...

Страница 8: ...R and associated accessories If Total Recall VR appears damaged then contact your supplier or us right away Save all packaging and if possible take photos that clearly show the damage to all packaging...

Страница 9: ...R W disc drive Use this drive to create archives of recordings on CD and DVD discs D Volume control Adjust the audio volume while monitoring or re playing recordings E Line out connector 3 5mm standa...

Страница 10: ...ls can be fitted C LAN port Total Recall VR LAN 1 port We recommend you use this port to connect Total Recall VR to you enterprise LAN On this model you must use this port to record VoIP calls as well...

Страница 11: ...g Search and Options Menu Dialog window Automatically moves the cursor to either the OK or Cancel button saving keystrokes Note that it does not actually activate the function that is attached to the...

Страница 12: ...ay Active re paly Pauses re play Active re play Fast forwards Recording on the Search Screen Shows the next group of 1000 recordings that are younger start time than the group already on the display A...

Страница 13: ...e becomes damaged then have it replaced immediately 6 Shut down and unplug Total Recall VR from telephone jacks and then from power outlets prior to moving or cleaning 7 Do not open Total Recall VR Th...

Страница 14: ...ure the outlet is grounded then have a qualified electrician check it 4 5 Local Area Network Connect Total Recall VR to an Ethernet network by attaching a network cable between the RJ45 jack with labe...

Страница 15: ...to input line 1 and 2 on the first connector The numbering then continues in lots of 2 with every adjacent connector The easiest way to connect Total Recall VR to the analogue telephone lines in order...

Страница 16: ...based VoIP packet collector which is capable of detecting extracting and then processing SIP RTP and H 323 packets when connected to an Ethernet link The packet collector does not interact with the p...

Страница 17: ...dio jack three conductor 3 5mm jack on the front panel Most headphones that are suitable for your PC will work with Total Recall VR The volume of the audio can be adjusted to a comfortable level with...

Страница 18: ...disk drive at a time If you connect multiple USB keys disk drives then Total Recall VR will write archives to the key drive that you connected FIRST To write archives to a specific key drive first di...

Страница 19: ...IP address of 192 168 1 100 24 The Remote Manager Interface accepts connections from client applications on IP address 192 168 1 100 and TCP port 10010 All recordings will be kept when recorded irresp...

Страница 20: ...nistrator Password 0000 Call Settings Disable Compression No Min Call Length Ignore Max Call Length 60 minutes Max Call Lifetime Ignore VOX Timeout 15 seconds Recording Period Not set always recording...

Страница 21: ...r VOX 4 Beep Off DTMF On Extension Not assigned ISDN Settings The ISDN configuration does not apply to your system VoIP Settings Signalling Type SIP Connection Type Local Connector LAN 2 TRVR Port 100...

Страница 22: ...ettings Time Date Date Set it to your current date Time Set it to your current time Time Zone Area Set it to your time zone area Time Zone City Set it to your city User Password Change the password to...

Страница 23: ...Total Recall VR Classic Desktop Page 23 of 32 We recommend that you restart Total Recall VR after completing the pre recording configuration...

Страница 24: ...tail This section contains a summary The GUI has 3 main screens Logging Screen Search Screen and Options Menu Screen Use the Menu key to switch from one screen to another as shown on the subsequent fi...

Страница 25: ...6 1 Recording You do not need to interact with the embedded GUI in any way to log audio or record calls Total Recall VR automatically records as instructed by its configuration Recordings that are in...

Страница 26: ...ordings on analogue channels where one to one mapping exists between audio sources and recording channels For example if you start monitoring a recording in progress that is using analogue recording c...

Страница 27: ...match the search criterion and display them sorted in reverse order of start time i e latest recording on top Figure 9 Search Screen with Search Result If the search results in 1000 recordings or less...

Страница 28: ...e key to pause and re start playing Press the key to stop playing 6 5 Archiving The embedded GUI makes provisions for on demand and automatic archiving 6 5 1 On Demand To archive a user defined set of...

Страница 29: ...ly you must replace full discs and make space on network disks as they become full To start automatic archiving all you need to do is enable and configure automatic archiving using the Archiving Setti...

Страница 30: ...beep to alert you to the fact that it is time to check and clean the filter Figure 13 Clean Filter Reminder Dialog Select OK to dismiss the dialog However at this point in time the filter should be w...

Страница 31: ...r the disk occupancy reaches 95 whichever occurs first It removes oldest first recordings until the number of recordings reduces to 300 000 or less and the disk occupancy is below 88 7 4 Orderly Shutd...

Страница 32: ...otal Recall VR or you are experiencing problems with your Total Recall VR then 1 Please visit the Resources section on our web site http www totalrecallvr com 2 Contact technical support via e mail tr...

Отзывы: