Wires of outdoor units
Single-phase unit:
TU36-24WADU
,
TU60-24WADU
.
①
.
High and low voltage wires should be led through different rubber rings of the
electric box cover.
②
.
Do not bundle up the thermostat wires or lay them side by side, otherwise
errors will occur.
③
.
High and low voltage wires should be secured separately. Secure the former
ones with big clamps and the latter ones with small clamps.
④
.
Use screws to tighten up the thermostat wires and power cords of the units on
the terminal board. Wrong connection may lead to fire hazard.
⑤
.
If the thermostat wires of the units and power cords are not correctly
connected, the air conditioner may get damaged.
⑥
.
Ground the units through connecting the ground wire.
⑦
.
The units should comply with applicable local and national rules and
regulations on power consumption.
⑧
.
When connecting the power cords, make sure the phase sequence of the
power supply matches with the corresponding terminals, otherwise the
compressor will get reversed and operate abnormally.