5
Technical Information
Service Manual
Outdoor
Unit
Cross-sectional Area of Power Cable Conductor
sq in
0.0051
Recommended Power Cable(Core)
N
3
Connection Pipe Connection Method
-
Flare Connection
Not Additional Gas Connection Pipe Length
ft
98.4
Connection Pipe Gas Additional Charge
oz/ft.
0.2
Outer Diameter of Liquid Pipe1(LENNOX Allocation)
(Metric)
inch
1/4
Outer Diameter of Liquid Pipe2(LENNOX Allocation)
(Metric)
inch
1/4
Outer Diameter of Liquid Pipe2(LENNOX Allocation)
(Metric)
inch
1/4
Outer Diameter of Gas Pipe1(LENNOX Allocation)
(Metric)
inch
3/8
Outer Diameter of Gas Pipe2(LENNOX Allocation)
(Metric)
inch
3/8
Outer Diameter of Gas Pipe2(LENNOX Allocation)
(Metric)
inch
3/8
Connection Pipe Max. Height Distance(indoor and
indoor)
ft
32.8
Connection Pipe Max. Height Distance(indoor and
outdoor and indoor up)
ft
32.8
Connection Pipe Max. Height Distance(indoor and
outdoor and outdoor up)
ft
32.8
Max. equivalent connection pipe length(outdoor to
last indoor)
ft
65.6
Connection Pipe Max. Length Distance(total lenght)
ft
196.8
The above data is subject to change without notice; please refer to the nameplate of the unit.