Table 11. Output Terminal Assignments for the
FLA/B/C
,
O1A/O1B
(OUT1),
O2A/O2B
(OUT2),
OUT3
-
OUT6
,
and
R1
-
R4
.
Discrete Output Terminal Assignment Selections
Input
Setting
Param.
Setting
Function
Input
Setting
Param.
Setting
Function
1000
0
LL: Lower-Limit Frequency
1064
64
Ready for Operation
1002
2
UL: Upper-Limit Frequency
1066
66
Under-Voltage of Control Power Alarm
1004
4
LOW: Low-Speed Signal
1068
68
Brake Release (BR)
1006
6
RCH: Acc/Dec Completion
1070
70
In Alarm Status (Alarm Status Active)
1008
8
RCH: Speed Reach Signal
1072
72
Forward Speed Limit (Torque Control)
1010
10
Failure FL (All Trips)
1074
74
Reverse Speed Limit (Torque Control)
1012
12
Failure FL (Except EF or OCL)
1076
76
ASD Healthy Output
1014
14
OC: Over-Current Pre-Alarm
1078
78
Abnormal Communication (Internal) Alarm
1016
16
OL1: ASD Overload Pre-Alarm
1106
106
Light Load Detection
1018
18
OL2: Motor Overload Pre-Alarm
1108
108
Heavy Load Detection
1020
20
OH: Over-Heat Pre-Alarm
1110
110
Torque Limit (Forward)
1022
22
OP: Over-Voltage Pre-Alarm
1112
112
Torque Limit (Reverse)
1024
24
MOFF: Main Circuit Under-Voltage Alarm
1114
114
Output for External Rush Suppression Relay
1026
26
Low-Current Alarm
1118
118
Completion of Stop Positioning
1028
28
Over-Torque Alarm
1120
120
Alarm Code 16
1030
30
DBR Overload Pre-Alarm (not used)
1122
122
Alarm Code 17
1032
32
In Emergency Off (Emergency Off Active)
1124
124
Alarm Code 18
1034
34
In Retry (Retry Active)
1126
126
Alarm Code 19
1036
36
Pattern Operation Switching Output
1128
128
Alarm Code 20
1038
38
PID Deviation Limit
1130
130
Alarm Code 21
1040
40
Run/Stop
1132
132
Alarm Code 22
1042
42
Serious Fault (OCA, OCL, EF, Phase Failure, etc.)
1134
134
Alarm Code 23
1044
44
Light Fault (OL, OC1, 2, 3, OP)
1136
136
Alarm Code 24
1046
46
Commercial Power/ASD Switching Output 1
1138
138
Alarm Code 25
1048
48
Commercial Power/ASD Switching Output 2
1140
140
Alarm Code 26
1050
50
Cooling Fan On/Off
1142
142
Alarm Code 27
1052
52
In Jogging Operation (Jogging Operation Active)
1144
144
Alarm Code 28
1054
54
Panel/Terminal Operation Switching
1146
146
Alarm Code 29
1056
56
Cumulative Run Time Alarm
1148
148
Alarm Code 30
1058
58
Abnormal Communication External Alarm (Cause) 1150
150
Alarm Code 31
1060
60
Forward/Reverse Switching
1152
152
FL3 (non EOFF trip) Status
1062
62
Ready for Operation (Including ST and RUN)
Содержание WX9 ASD
Страница 1: ...WX9 ASD Install Op Manual TOSHIBA WX9 ASD INSTALLATION OPERATION MANUAL DN 68940 000 March 2014 ...
Страница 2: ......
Страница 3: ...DN 68940 000 March 2014 WX9 ASD Installation Operation Manual ...
Страница 4: ......
Страница 12: ...iv WX9 ASD Installation and Operation Manual ...
Страница 213: ...WX9 ASD Installation and Operation Manual 201 Figure 32 WX9 ASD Enclosure Dimensions Dimensions are in in mm ...
Страница 225: ......