Speed at F320 Drooping Gain
Program
Feedback
Drooping Control
This parameter sets the motor speed when at the 100% output torque gain while
operating in the
Drooping
Control
mode. This function determines the speed
of the individual motors at the 100%
Drooping Gain
setting for motors that
share the same load.
Direct Access Number — F322
Parameter Type —
Numerical
Factory Default —
60.00
Changeable During Run —
Yes
Minimum — 0.00
Maximum — 299.0
Units — Hz
Drooping Insensitive Torque
Program
Feedback
Drooping Control
This parameter defines a torque range in which the
Drooping
Control
settings
will be ignored and the programmed torque settings will be followed.
Direct Access Number — F323
Parameter Type —
Numerical
Factory Default —
10.00
Changeable During Run —
Yes
Minimum — 0.00
Maximum — 100.0
Units — %
Drooping Output Filter
Program
Feedback
Drooping Control
This parameter is used to set the rate of output change allowed when operating
in the
Drooping Control
mode.
Jerky operation may be decreased by increasing this setting.
Direct Access Number — F324
Parameter Type —
Numerical
Factory Default —
100.0
Changeable During Run —
Yes
Minimum — 0.1
Maximum — 200.0
Load Inertia (Acceleration/Deceleration Torque)
Program
Feedback
Drooping Control
This parameter is used for calculating Acceleration/Deceleration torque when
compensating for load inertia while operating in the
Drooping Control
mode.
Direct Access Number — F325
Parameter Type —
Numerical
Factory Default —
1.0
Changeable During Run —
Yes
Minimum — 0.0
Maximum — 1000.0
Load Torque Filter
Program
Feedback
Drooping Control
This parameter is used to set the response sensitivity when calculating the
Acceleration/Deceleration torque. This setting applies to load inertia
compensation while operating in the
Drooping Control
mode.
This parameter should be gradually adjusted to provide smoother
Drooping
Control
operation while operating with heavy loads.
Direct Access Number — F326
Parameter Type —
Numerical
Factory Default —
200.0
Changeable During Run —
Yes
Minimum — 0.0
Maximum — 200.0
Drooping Reference
Program
Feedback
Drooping Control
This parameter sets the method to be used in determining the output torque
while operating in the
Drooping Control
mode.
Settings:
0 — Total Torque Calculated by the Detection Current
1 — Torque without Acc/Dec Torque Calculated by Detection Current
2 — Total Torque Calculated by the Command Current
3 — Torque without Acc/Dec Torque Calculated by the Command Current
Direct Access Number — F327
Parameter Type —
Selection List
Factory Default —
Total torque
calculated by the
detection current
Changeable During Run —
Yes
Содержание WX9 ASD
Страница 1: ...WX9 ASD Install Op Manual TOSHIBA WX9 ASD INSTALLATION OPERATION MANUAL DN 68940 000 March 2014 ...
Страница 2: ......
Страница 3: ...DN 68940 000 March 2014 WX9 ASD Installation Operation Manual ...
Страница 4: ......
Страница 12: ...iv WX9 ASD Installation and Operation Manual ...
Страница 213: ...WX9 ASD Installation and Operation Manual 201 Figure 32 WX9 ASD Enclosure Dimensions Dimensions are in in mm ...
Страница 225: ......