Cautions on Safety 

 

Cautions for Installation

WARNING

When Heat Exchange Ventilators are 
relocated, contact your dealer or a 
professional installer.

Improper practice of 
installation could cause 
a drop of the unit, a 
water leakage, an 
electric shock or a fire.

Ask the sales office or the 
engineering shop to perform the 
work.

The external air intake opening should 
be positioned away from the exhaust 
openings of combustion gases etc.

The intake of such gasses 
could lead to a lack of 
oxygen in the room.

The external air intake opening 
should not be positioned where 
discharged air may directly enter it.

A situation like this will 
lead to the room being 
contaminated and this 
may pose a health risk.

Cautions for 
Maintenance

Cautions for Operation

WARNING

CAUTION

When the system is checked and the 
power cable undergoes maintenance, 
stop the operation, and switch the 
exclusive circuit breaker "OFF".

The internal fan is revolving at high 
speeds and can cause serious injury. 
And when using a stepladder,  etc., 
make sure to fix it properly.

Combustion apparatus should not be 
placed allowing a direct exposure to 
wind of Heat Exchange Ventilators.

Incomplete combustion 
could occur on the 
apparatus.

Don't blow directly towards animals or 
plants.

Likely to cause bad effect on animals 
and plants.

Don't put a container of water on Heat 
Exchange Ventilators.

When water spills, it is 
likely to enter inside the 
unit and degrade electric 
insulation, possibly 
resulting in an electric 
shock.

Do not wash Heat Exchange 
Ventilators with water.

It could cause an electric 
shock.

Do not handle switches with a wet 
hand.

It could cause an electric 

shock.

If Heat Exchange Ventilators are not 
used for a long period of time, switch 
the exclusive circuit breaker "OFF" for 
safety reasons.

If the power is left on, any build-up of 
dust could cause a heat generation or 
a fire.

It is strictly prohibited to place a 
container of combustible gas or liquid 
near Heat Exchange Ventilators or to 
spray it directly with the gas or liquid.

It could cause a fire.

Do not use outside the rated voltage.

It could cause a fire or 
an electric shock.

Never Fail to Observe

Prohibited

ON

OFF

Prohibited

Prohibited

Prohibited

Keep from 

water

Don’t touch 

with wet hands

ON

OFF

Prohibited

Prohibited

VN250_OM-01EN.fm  Page 3  Thursday, September 8, 2005  10:31 AM

Содержание VN-1KTAE

Страница 1: ...A Manual do proprietário Εξαεριστήρες Ανταλλαγής Θερµότητας TOSHIBA Εγχειρίδιο Ιδιοκτήτη VN 500TE Model No N de modèle Modell Nr Modello N Modelo N Modelnr Nº do modelo Αρ Μοντέλου VN 250TE VN 350TE VN 500TE VN 800TE VN 1KTAE Installation manual is attached separately Le manuel d installation est joint séparément Installationsanleitung ist gesondert beigelegt Il manuale di installazione è allegato...

Страница 2: ...VN250_OM 00CV fm Page 2 Thursday September 8 2005 10 42 AM ...

Страница 3: ...is owner s manual with care so that you can use the unit correctly After reading it please keep it so you can read it whenever necessary CONTENTS Cautions on Safety 2 5 Features 5 Name of Each Part 6 Specific Caution Items 7 Model Installation 8 Maintenance Method 9 12 After sales Service 12 Specifications 13 14 VN250_OM 01EN fm Page 1 Thursday September 8 2005 10 31 AM ...

Страница 4: ... stick into the air inlet or the outlet A fan with a high rpm will injure you Modification of the system is strictly prohibited Improper practice of repair could cause a water leakage an electric shock or a fire When the system needs a repair consult your dealer If there is a combustible gas leakage from other appliances ventilate the room by opening windows If operation were to be attempted in su...

Страница 5: ... fix it properly Combustion apparatus should not be placed allowing a direct exposure to wind of Heat Exchange Ventilators Incomplete combustion could occur on the apparatus Don t blow directly towards animals or plants Likely to cause bad effect on animals and plants Don t put a container of water on Heat Exchange Ventilators When water spills it is likely to enter inside the unit and degrade ele...

Страница 6: ...uit breaker that can completely break contacts on all the poles by more than 3mm through direct connection to the power terminals Depending upon the environment for installation it becomes necessary to install an earth leakage breaker Unless the earth leakage breaker is installed it could cause an electric shock Ask the sales office or the engineering shop to perform the work Do not install in loc...

Страница 7: ...ation is available with least possible fluctuation of a room temperature Since exhaust and air intake are performed simultaneously a stable ventilation is possible even in a highly airtight room 5 Sound shield effect The ducts of the unit and the heat exchange element are characteristic of sound shield effect Thus it prevents an outside noise from coming in the unit and also sound inside the unit ...

Страница 8: ...322 884 388 VN 1KTAE 1322 1134 388 EA Exhaust Air OA Outside Air Heat Exchange Element Inspection Cover Electrical Equipment Box RA Room Air Filter SA Supply Air C B A EA Exhaust Air OA Outside Air Heat Exchange Element Inspection Cover Electrical Equipment Box RA Room Air Filter SA Supply Air RA Room Air SA Supply Air Maintenance Space 450 EA Exhaust Air OA Outside Air Inspection Opening VN250_OM...

Страница 9: ...or Heat Exchange Element become clogged with oil Make sure that Inspection Opening is provided so that filter and Heat Exchange Element maintenance and periodic spot checks of the unit can be easily carried out Refer to the Model Installation for its space Do not install the unit in locations such as machinery or chemical plants where it will be exposed to noxious gases containing acids alkali org...

Страница 10: ...immerse the filter or other resin components in water 60 C or above Never use water on the motor the switch or the Heat Exchange Element Do not use the following items for cleaning Avoid using heat to dry the filter as it may cause changes in shape or quality Always be sure to use a filter Failure to do so may cause dust and dirt to build up on the heat exchange element lowering its efficiency and...

Страница 11: ...m water and dish washing neutral detergent 5 Install the filter after thoroughly allowing it to dry naturally Caution Whenever the filter was damaged order the sales shop or the engineering office Separately sold Cleaning the Heat Exchange Element If you find it too much stained clean it 1 Remove the filters 2 Remove the two Heat Exchange Elements from the unit Model No VN 250TE has one Heat Excha...

Страница 12: ...e screw Caution Clean by lightly pressing the vacuum cleaner nozzle against the exterior Avoid using a hard nozzle as it may disfigure the heat exchange foils Never use water to clean the Heat Exchange Element Make sure to install the filter with the stamp facing the Heat Exchange Element means Heat Exchange Element side Failure to do so will lead to clogging of the heat exchange foils and reduced...

Страница 13: ... Install the filter after thoroughly allowing it to dry naturally Install them to fit well with the grooved rail Caution Whenever the filter was damaged order the sales shop or the engineering office Separately sold Cleaning the Heat Exchange Element If you find it too much stained clean it 1 Remove the four Heat Exchange Elements from the unit Model No VN 800TE has three Heat Exchange Elements Ca...

Страница 14: ...tact the store where you bought your unit or the agent who installed it to request servicing or consultation Clean by lightly pressing the vacuum cleaner nozzle against the exterior Avoid using a hard nozzle as it may disfigure the heat exchange foils Never use water to clean the Heat Exchange Element Make sure to install the filter with the stamp facing the Heat Exchange Element means Heat Exchan...

Страница 15: ...igh Low Input W 137 154 178 124 137 149 117 128 132 133 151 176 119 132 145 113 125 131 Air Volume m3 h 350 350 350 350 280 240 350 350 350 350 280 240 External Static Pressure Pa 95 155 65 90 42 43 95 155 65 90 42 43 Noise dB 31 32 33 29 30 30 25 26 22 31 32 33 30 31 30 26 27 23 Temperature Exchange Efficiency 75 75 75 75 77 79 Dimensions mm Width 882 x Depth 804 x Height 270 Weight kg 37 Model N...

Страница 16: ...External Static Pressure Pa 140 190 110 100 70 50 140 190 110 100 70 50 Noise dB 38 39 39 36 5 37 5 36 32 34 31 38 5 39 5 39 5 37 38 37 33 35 31 Temperature Exchange Efficiency 75 75 75 75 76 77 Dimensions mm Width 1322 x Depth 884 x Height 388 Weight kg 71 Model No Item VN 1KTAE Power Source 220 240V 50Hz Ventilation Mode Heat Exchange Ventilation Normal Ventilation Notch Extra high High Low Extr...

Страница 17: ...er our sole responsibility that the product Heat Exchange Ventilator to which this declaration relates is in conformity with the provisions of Council Directive 89 336 EEC Electromagnetic Compatibility and 73 23 EEC Low Voltage Directive TJ0412 Printed in Japan VN250_OM 00CV fm Page 3 Thursday September 8 2005 11 03 AM ...

Отзывы: