6-1
6. [Advanced] How to use parameters
I
II
III
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
This inverter has basic parameters and other three types of parameters such as extended
parameters (with F), advanced parameters, (with A), and communication parameters (with C).
These parameters are used for sophisticated operations, detailed settings, special purposes, etc.
This chapter explains how to use the parameters that are not mentioned in the previous chapters.
Various signals are output for motor operation.
For details on the output terminal functions, refer to [7. 2. 2].
6. 1. 1
Output the running signal and the brake signal
(output the low-speed signal)
<F100: Low-speed signal output frequency>
■
Function
When the output frequency becomes over <F100: Low-speed signal output frequency>, the low-
speed signal is output from the output terminal.
• When <F100: Low-speed signal output frequency> is set to "0.0", the ON signal is output when the
output frequency is over 0.0 Hz. Therefore, this setting can be used as a running signal.
• This signal can be also used as brake/release signal for the electromagnetic brake.
■
Parameter setting
6
[Advanced]
How to use parameters
6. 1
Output signals from the control terminals
Title
Parameter name
Adjustment range
Unit
Default setting
F100
Low-speed signal output
frequency
0.0-FH
Hz
0.0
0.0Hz
STOP
12:42
F100 : Low-speed signal freq
Min: 0.0
Max: 80.0
X1000
X100
X10
X1
Hz
0.0
Содержание TOSVERT VF-AS3
Страница 2: ...1 9 ...
Страница 14: ......
Страница 17: ...E6582062 iii I 3 9 15 Warranty 15 1 16 Disposal 16 1 ...
Страница 18: ......
Страница 34: ......
Страница 438: ......
Страница 458: ......
Страница 470: ......
Страница 482: ......
Страница 502: ......
Страница 572: ......
Страница 590: ......
Страница 608: ......
Страница 616: ......
Страница 618: ......
Страница 620: ......
Страница 621: ...1 3 9 10 ...