1-40
Step
Figure
Explanation
4
5
6
7
(1) Monitor the waveform at the test point "TP-R".
(2) Click [WM7] button and adjust to the specified level.
(3) Check the voltage at the test points "TP-R" and "TP-B".
(4) Click [Next] button.
[Note]
"G" and "B" levels also change when [WM7] adjustment
is performed.
(1) Monitor the waveform at test point "TP-R".
(2) Click [W03] button and adjust to the specified level.
( [W09] and [W0C] are the same process.)
(3) Click [Next] button.
(1) Monitor the waveform at test point "TP-G".
(2) Click [W04] button and adjust to the specified level.
( [W0A] and [W0D] are the same process.)
(3) Click [Next] button.
(1) Monitor the waveform at test point "TP-B".
(2) Click [W05] button and adjust to the specified level.
( [W0B] and [W0E] are the same process.)
(3) Click [Next] button.