STE80753
– 64 –
TRANSPORTATION AND INSTALLATION MANUAL
5.
The cables connecting the panel
with the actuator are fabricated long
so that the panel can be mounted on
the lower side, and are secured to
the bracket with TY-RAP.
Cut the secured TY-RAP, using
nippers, etc., extend the cables, then
connect the connectors coming from
the panel. After the connection,
secure the cables to the guide, using
the TY-RAP so that the cables will
not collide with the axis 3 or 4 belt.
Secure any loosened cable to the
bracket also, using the TYRAP.
6. Finally, secure the cover
disconnected in Step 3 to the location
where the panel was mounted
before, then attach the cover. At
this time, be sure to set the nylon
washers.
Take careful precautions not to
damage the cover.
Fig. 5.4 (2) Procedures for relocating wiring panel
!
CAUTION
• Be sure to connect all connectors properly. Otherwise, the robot may
malfunction.
• Take careful precautions not to interfere the cables with the belts.
Otherwise, the cables may break.
• When relocating the panel, take utmost care not to damage the belts.
Guide
Bracket