- 60 -
Supplementary Explanation
• When the [RESTART] and [FEED] keys are pressed at the same time, the display shows
the system mode menu.
• If the [RESTART] or [FEED] key is held down for 0.5 seconds or more when a fine
adjustment value is being set, the printer enters the repeat mode, in which the key is
entered repeatedly.
• A changed fine adjustment value is stored in memory by pressing the [PAUSE] key.
• The printer is controlled by the sum of the fine adjustment parameter programmed on the
printer and the fine adjustment command from the PC. However, the maximum values
for each fine adjustment are as follows:
Feed fine adjustment ...................................................................±50.0 mm
Cut position (stop position of the strip issue) fine adjustment .....±50.0 mm
Back feed fine adjustment ...........................................................±9.9 mm
Print density fine adjustment
Thermal transfer print mode ....................................................±10 step
Direct thermal print mode ........................................................+6 step or -10 step
X-coordinate fine adjustment .......................................................±99.5 mm
Ribbon motor drive voltage fine adjustment (Rewind) .................+6 step or -15 step
Ribbon motor drive voltage fine adjustment (Back tension) ........+10 step or -15 step
• The X-coordinate fine adjustment is performed to finely adjust the X-coordinate of the
drawing in the left or right direction. Adjust the X-coordinate in the effective print range.
(After the value reaches the coordinate “0”, the value remains unchanged even if a
subsequent fine adjustment is performed in the negative direction.)
• The X-coordinate fine adjustment is not effective for the self-test results printout
(maintenance counter, various parameters, and automatic self-test) and the test print.
• The print density fine adjustment value is +0 step at the time of shipment from the factory.
• The ribbon motor drive voltage fine adjustment value is each the sum of the fine
adjustment by command (from the PC) and the fine adjustment in the system mode (by
key operation). The maximum fine adjustment values are +6 or -15 for the ribbon rewind
motor, and +10 or -15 for the ribbon back tension motor.
• The print density fine adjustment value is the sum of the fine adjustment by command
(from the PC) and the fine adjustment in the system mode (by key operation). The
respective max. fine adjustment values are ±10. (For the direct thermal print mode, the
maximum fine adjustment value is +6 or -10.)