– 9 –
6
Regarding antibacterial glass
This product has internal antibacterial glass. Antibacterial glass is a consumable part. It should be replaced after about 10,000
hours of regular air conditioner operation. (If the air conditioner is operated 10 hours every day for five months, that is 1,500
hours for the year.) Use the antibacterial glass holder (service part No. : 43479037) when you replace it.
Replacing antibacterial glass
1
Remove the screw holding the cover of the antibacterial glass holder.
2
The cover of the antibacterial glass holder has a hook, lift the cover up as you remove it.
(Refer to Fig.1 and Fig.2)
3
Remove the antibacterial glass holder that is hanging inside the drain pump kit through the hole that is in
the top.
(Refer to Fig.3)
4
Insert the new antibacterial glass holder and securely close the cover of the antibacterial glass holder and
fasten it in place.
(The top of the cover of the antibacterial glass holder is a hook that hooks to the drain pump kit. Make sure
that it is secure.)
Fig.1
Fig.2
Fig.3
Cover of the antibacterial glass holder
Remove this screw and then remove the cover
of the antibacterial glass holder
2
1
Hook
Antibacterial glass holder
+00EH99545701_00Ta.book Page 9 Wednesday, June 5, 2013 2:38 PM