21
Power Connection
1. Connect
POSITIVE
24 volt AC power to pin
1
.
2. Connect ground wire to pin
2
.
3. Connect
NEGATIVE
24 volt AC power to pin
3
.
Note
The ‘notches’ on the left side of the graphic above
correspond to notches in the green plastic of the power connector.
Note
Be careful not to pull the cables improperly during installation. Toshiba
suggests that you fasten the cables after installation is complete.
Grounding Recommendation
The GND (ground) wire must be directly connected to the middle pin of the AC24V
power connector. Failure to connect the ground can cause damage and failure of the
camera and may void the warranty.
Ethernet Cable Connection
Connect one end of the CAT 5 Ethernet cable to the RJ-45 connector of the camera and
the other end of the cable to the network switch or recorder.
Note
In some cases, you may need to use an Ethernet crossover cable when
connecting the camera directly to the recorder.
Check the status of the link indicator and activity indicator LEDs. If the LEDs are unlit,
check the LAN connection.
The Green link light indicates a good network connection.
The Orange activity light flashes to indicate network activity.