ONEAC 400 UPS
Stratagy General Description 01/03
55
Table 6
Stratagy Hardware Environmental and Electrical Specification Summary
Environmental
Conditions
Operating Temperature
39.2
º
F~104
º
F (4
º
C~40
º
C)
Storage Temperature
104
º
F~140
º
F (40
º
C~60
º
C)
Operating Humidity
20%~80% (non-condensing)
Electrical
Requirements
(AC Input)
Stratagy Enterprise Server (ES)
115VAC, at 6 amps (50/60 Hz) – standard
230VAC at 3.5 amps (50/60 Hz)– switch configured
Optional Monitor
115VAC at 0.5 amps (50/60 Hz)
Provide host system with 15A circuit breaker and dedicated circuit.
Heat Dissipation
Stratagy Enterprise Server (ES)
Maximum 200 watts, 685 BTU per hour
Optional Monitor
Maximum 50 watts, 200 BTU per hour
Analog Interface
Telco types
Loop Start, OPX, T1
Connection
Single line, RJ14C and RJ11C jacks; RJ48C (T1)
Impedance
600 ohm nominal
Frequency response
300~3200 Hz
Ring detect
40~130 Vrms, 15.3~68.0 Hz
Loop current range
20~120 mA
polarity insensitive
Transfer signaling
Hookflash
Input level
-30 dB~-3 dB
Output level
-30 dB~-3 dB
DTMF receive
Minimum tone duration
Minimum tone detect
Twist range
16 tones (0~9,
*
, #, A~D)
45 ms
–29 dB/minimum
±10 dB
DTMF transmit
Minimum tone duration
Transmit level
Twist range
16 tones (0~9,
*
, #, A~D)
50 ms
–7 dBm nominal
2~3 dB
Progress Tones
Standard and proprietary, in 350~640 Hz frequency
range
Frequency response
200~300 Hz ± 3 dB/minimum
Speech Parameters
–13 dB/minimum average transmit level for a –32
dBm receive level
Voice Coding Scheme
64 Kbs u-Law PCM, 32 Kbs ADPCM compression
Содержание Stratagy ES4
Страница 6: ......
Страница 10: ...Contents Chapter 4 Specifications iv Stratagy General Description 01 03 ...
Страница 30: ...Overview Feature System Comparison Chart 18 Stratagy General Description 01 03 ...
Страница 54: ...Features Telephone System Integration 42 Stratagy General Description 01 03 ...
Страница 68: ...Specifications ONEAC 400 UPS 56 Stratagy General Description 01 03 ...