WinCIX Off-line Programming for Strata CIX

4 of 5

7. Click the Connect Now button. eManager should connect to WinCIX and operate exactly as if it were 

connected to a CIX system.

Note

In the PC Local Area Connection Property Settings, you may need to set the PC Internet Protocol 
(TCP/IP) properties to use the following recommended IP address: 192.168.254.251. Subnet mask: 
255.255.255.0.

8. Make your Off-line programming changes from eManager.

9. When you are done programming, select Operation > Data Backup. Click the Back Up button. When 

you see “Completed Successfully,” it is done. This will create a new “default.dat” file that contains your 
programming changes.

Important!

Data changes will not be stored in the default.dat file unless you backup your data using 
eManager.

10.Log out of WinAdmin and then bring up the WinCIX application screen and click the Stop button to 

stop WinCIX (see “

Stopping WinCIX

”). 

11. To transfer the WinCIX database to a CIX system, locate the “default.dat” file in the folder previously 

selected in Step 4.

12.Transfer the “default.dat” file to a SmartMedia card (progdata folder) in the CIX, either locally or 

remotely, and then restore the data to the CIX using the system initialization procedure (Program 900 
level 1). For more information, see the Strata CIX Programming manual, Chapter 10–Operation, “900 
CIX Restart.”

Stopping WinCIX

1. Click the Stop button or click 

the 

 button in the right corner. 

WinCIX displays window 
(shown right)

.

2. Click Yes to stop WinCIX

...or click No to continue using 
WinCIX. 

Important!

Data changes will not be stored in the default.dat file unless you backup your data using 
WinAdmin.

Viewing the CIX Release Number Supported by WinCIX

To display the CIX release number supported by WinCIX, open WinCIX and click on the WinCIX icon in 
the left corner, then click on the “version number WinCIXR400XXnnn.” The CIX release (R4.00) and 
build (MLnnn) number that WinCIX will emulate when it is running displays.

When you run WinCIX, it always shows the same CIX release and build information even if you open a 
default.dat file with different release and build numbers. You can restore the “default.dat” files created by 
WinCIX to CIX systems with different release numbers per the rules that follow. 

Содержание Strata CIX WinCIX

Страница 1: ...y table last page before using particular versions of WinCIX on the Strata CIX system 2 Always make a copy of original default dat files before you open and edit them using WinCIX In an emergency situation you may need the original default dat file to restore your original data to the CIX system Tips and Limitations 1 The Download function of eManager is not supported with WinCIX Off line programm...

Страница 2: ...open the correct version see Rules for Opening Restoring default dat files 2 Run WinAdmin and connect to WinCIX select Local WinCIX 127 0 0 1 CAUTION Always make a copy of original default dat files before you open and edit them using WinCIX In an emergency situation you may need the original default dat file to restore your original data to the CIX system 3 Edit the database using CIX eManager 4 ...

Страница 3: ...ways make a copy of original default dat files before you open and edit them using WinCIX In an emergency situation you may need the original default dat file to restore your original data to the CIX system 5 Click the Start button The window shown right appears If a default dat file exists in the selected folder the window shown right displays ä Click Yes to load the default dat file into WinCIX ...

Страница 4: ... selected in Step 4 12 Transfer the default dat file to a SmartMedia card progdata folder in the CIX either locally or remotely and then restore the data to the CIX using the system initialization procedure Program 900 level 1 For more information see the Strata CIX Programming manual Chapter 10 Operation 900 CIX Restart Stopping WinCIX 1 Click the Stop button or click the button in the right corn...

Страница 5: ...h the release of new software Programming Data File Name You can now name the programming data file default default dat whatever you want based on the following rules MS DOS file Maximum character length 8 does not include the extension Minimum character length 1 Extension must be dat example tais a02 dat The following characters cannot be used CIX Software WinCIX Version R3 0 MJ038 MJ041 R300MJ03...

Отзывы: