background image

November, 2007

WinCIX Off-line Programming for Strata CIX

3 of 5

SNMP service to prevent connection problems between WinAdmin and WinCIX. After stopping 
SNMP service(s), click OK to continue. 

3. Select a Region Code: 

Click the down arrow and 
highlight a country. The 
Region Code is the same as 
country list in Program 
915-04.

4. Select the Access Folder: 

This is where the 
“default.dat” file will be 
stored. The empty default 
folder is 
“C:/WINCIX/SM/”. 

If you want to use a 
different folder that 
contains a default.dat file 
or create a new 
“default.dat” file, click Browse. The Searching Access Folder window displays. Select a folder, then 
click Set.

To edit an existing “default.dat” file, select the folder that contains the “default.dat” file which should 
be edited.

CAUTION!

Always make a copy of original default.dat files before you open and edit them using 
WinCIX. In an emergency situation you may need the original default.dat file to 
restore your original data to the CIX system.

5. Click the Start button. The window shown right 

appears.

If a “default.dat”file exists in the selected folder, 
the window (shown right) displays: 

ä

Click Yes to load the “default.dat” file into 
WinCIX. WinCIX shows “Restoring,” as it loads 
the existing default.dat. 

If a “default.dat” file is not in the selected folder, 
the “Load default.dat?” screen does 

not

 appear and 

WinCIX immediately displays the “WinCIX is running” screen. You can still connect to WinCIX to 
create a new default.dat file in the selected folder by continuing with the following steps. 

6. With WinCIX running, log on to eManager.

Enter CIX IP/Name (IP address): 127.0.0.1 or your local PC’s IP address.

Enter a Community Name (CIX default is “communityName”).

Shows the type 
of CIX database 
supported.

7054

Содержание Strata CIX WinCIX

Страница 1: ...y table last page before using particular versions of WinCIX on the Strata CIX system 2 Always make a copy of original default dat files before you open and edit them using WinCIX In an emergency situation you may need the original default dat file to restore your original data to the CIX system Tips and Limitations 1 The Download function of eManager is not supported with WinCIX Off line programm...

Страница 2: ...open the correct version see Rules for Opening Restoring default dat files 2 Run WinAdmin and connect to WinCIX select Local WinCIX 127 0 0 1 CAUTION Always make a copy of original default dat files before you open and edit them using WinCIX In an emergency situation you may need the original default dat file to restore your original data to the CIX system 3 Edit the database using CIX eManager 4 ...

Страница 3: ...ways make a copy of original default dat files before you open and edit them using WinCIX In an emergency situation you may need the original default dat file to restore your original data to the CIX system 5 Click the Start button The window shown right appears If a default dat file exists in the selected folder the window shown right displays ä Click Yes to load the default dat file into WinCIX ...

Страница 4: ... selected in Step 4 12 Transfer the default dat file to a SmartMedia card progdata folder in the CIX either locally or remotely and then restore the data to the CIX using the system initialization procedure Program 900 level 1 For more information see the Strata CIX Programming manual Chapter 10 Operation 900 CIX Restart Stopping WinCIX 1 Click the Stop button or click the button in the right corn...

Страница 5: ...h the release of new software Programming Data File Name You can now name the programming data file default default dat whatever you want based on the following rules MS DOS file Maximum character length 8 does not include the extension Minimum character length 1 Extension must be dat example tais a02 dat The following characters cannot be used CIX Software WinCIX Version R3 0 MJ038 MJ041 R300MJ03...

Отзывы: