Strata CTX670 Installation
3-8
Strata CTX I&M September 2002
Check the Power Factor Indicator and Reset Button
The front panel of BPSU672A provides a Power Factor LED and Reset button. If the cabinet power
factor is exceeded by overload of PCBs, the PF LED will turn on.
➤
If the PF LED indicator turns on, press the PF reset button with a pointed tool or pencil. If the PF
LED turns off and does not turn on again it may have been turned on by a current surge while
installing a PCB while the power supply was turned-on.
➤
When a PF alarm is indicated, check that the cabinet power factor is not exceeded using the
“System Power Factor Check Considerations” on Page 1-27
. If the Power factor has been
exceeded relocate any PCBs that are causing the PF to be exceeded.
Power Supply (BPSU672) Removal
1. Remove the front and right side covers (
) from the cabinet. Remove the right side covers
of other cabinets as needed to disconnect wiring.
2. Turn the power supply Off, and disconnect the AC power cord, all ground wiring and reserve
power cabling that is connected to the power supply.
3. Disconnect the back plane DC OUT cable plug from the DC OUT connector.
4. Loosen the four mounting screws securing the power supply to the cabinet and remove the power
supply.
Power Supply Replacement
➤
Install the replacement power supply per
Содержание Strara CTX Series
Страница 10: ...Contents viii Strata CTX I M September 2002 ...
Страница 14: ...Introduction xii Strata CTX I M September 2002 ...
Страница 52: ...Strata CTX Configuration 1 38 Strata CTX I M September 2002 ...
Страница 176: ...ISDN Interfaces 5 28 Strata CTX I M September 2002 ...
Страница 278: ...Peripheral Installation 8 32 Strata CTX I M September 2002 ...
Страница 290: ...Index IN 6 Strata CTX I M September 2002 ...