MDF PCB Wiring
6-4
Strata CTX I&M September 2002
Station Wiring Diagrams
Standard
Telephone
Building #1
Building #2
PCOU, RCOU/RCOS
RGLU, RCIU/RCIS,
RBUU/RBUS,
RBSU/RBSS,
RMCU/RCMS
Digital
Telephone
Digital Telephone
or Cordless Base
E&M Tie Line
Ground/Loop/ISDN BRI/
E911 CAMA Lines
Secondary protectors – standard voltage
Secondary protectors – low voltage
MDFB
DDCB
DDSS
Console
HESB
RPTU
REMU
POW
DTR
DSR
BATI
Console Handset
PC
Attendant
Console
DDCB
MDFB
DDI & ISDN PRI Line
Earth Ground
Earth Ground
CSU
PSTU
RSTU/RSTU2/
RSTU3/
RDSU/RSTS
5655
ADKU,
BDKU/BDKS
or PDKU
Important!
To protect against transient voltages and currents, solid state secondary protectors
must be installed if there is outside wiring, and on all DDI and E&M Tie lines.
These protectors, which contain fast semiconductors in addition to fuses, shall
comply with the requirements for secondary protectors for communication circuits.
Care must be taken to ensure that they are very well grounded to a reliable earth
ground. Install and test the secondary protectors precisely to the installation
instructions of the manufacturer.
Figure 6-1
Strata CTX Secondary Protector Diagram
Содержание Strara CTX Series
Страница 10: ...Contents viii Strata CTX I M September 2002 ...
Страница 14: ...Introduction xii Strata CTX I M September 2002 ...
Страница 52: ...Strata CTX Configuration 1 38 Strata CTX I M September 2002 ...
Страница 176: ...ISDN Interfaces 5 28 Strata CTX I M September 2002 ...
Страница 278: ...Peripheral Installation 8 32 Strata CTX I M September 2002 ...
Страница 290: ...Index IN 6 Strata CTX I M September 2002 ...