Troubleshooting Procedures
PORTEGE R830 Satellite R830 Series Maintenance Manual (960-880) [CONFIDENTIAL]
2-11
If the diagnostics program cannot detect an error, the problem may be intermittent. The Test
program should be executed several times to isolate the problem. Check the Log Utilities
function to confirm which diagnostic test detected an error(s), then perform the appropriate
troubleshooting procedures as follows:
1.
If an error is detected on the power supply , perform the power supply Troubleshooting
Procedures in Section 2.3.
2.
If an error is detected on the system test, memory test, display test, CD-ROM/DVD-
ROM test, expansion test, real timer test, sound test or Modem/LAN/Bluetooth
/IEEE1394 test, perform the System Board Troubleshooting Procedures in Section 2.4.
3.
If an error is detected on the floppy disk test, perform the USB FDD Troubleshooting
Procedures in Section 2.5.
4.
If an error is detected on the hard disk test, perform the HDD/SSD Troubleshooting
Procedures in Section 2.6.
5.
If an error is found on the keyboard test (DIAGNOSTICS TEST) and pressed key
display test (ONLY ONE TEST), perform the Keyboard Troubleshooting Procedures
in Section 2.7.
6.
If an error is found on the touch pad test (ONLY ONE TEST), perform the touch pad
Troubleshooting Procedures in Section 2.8.
7.
If an error is detected on the display test, perform the Display Troubleshooting
Procedures in Section 2.9.
8.
If an error is detected on the CD-ROM/DVD-ROM test, perform the Optical Disk
Drive Troubleshooting Procedures in Section 2.10.
9.
If an error is detected on the LAN test, perform the LAN Troubleshooting Procedures
in Section 2.11.
10.
If an error is detected on the wireless LAN test, perform the Wireless LAN
Troubleshooting Procedures in Section 2.12.
11.
If an error is detected on the Bluetooth test, perform the Bluetooth Troubleshooting
Procedures in Section 2.13.
12.
If an error is detected on the sound test, perform the Sound Troubleshooting
Procedures in Section 2.14.
13.
If an error is detected on the sound test, perform the SD Card Troubleshooting
Procedures in Section 2.15.
14.
If a malfunction is detected on the PCI ExpressCard, perform the PCI ExpressCard
Troubleshooting Procedures in Section 2.16.
Содержание Satellite R830
Страница 12: ...1 Hardware Overview 1 2 CONFIDENTIAL PORTEGE R830 Satellite R830 Series Maintenance Manual 960 880 ...
Страница 43: ...Troubleshooting Procedures 2 2 PORTEGE R830 Satellite R830 Series Maintenance Manual 960 880 CONFIDENTIAL 2 ...
Страница 111: ...Tests and Diagnostics 3 2 CONFIDENTIAL PORTEGE R830 Satellite R830 Series Maintenance Manual 960 880 3 ...
Страница 289: ... CONFIDENTIAL Chapter 4 Replacement Procedures ...
Страница 290: ...4 Replacement Procedures 4 ii CONFIDENTIAL PORTÉGÉ R830 Satellite R830 Maintenance Manual 960 880 ...
Страница 294: ...4 Replacement Procedures 4 vi CONFIDENTIAL PORTÉGÉ R830 Satellite R830 Maintenance Manual 960 880 ...
Страница 414: ...4 Replacement Procedures 4 28 Hinge 4 120 CONFIDENTIAL PORTÉGÉ R830 Satellite R830 Maintenance Manual 960 880 ...
Страница 415: ... CONFIDENTIAL Appendices ...
Страница 416: ...Appendices App ii CONFIDENTIAL PORTEGE R830 Satellite R830 Series Maintenance Manual 960 880 ...
Страница 424: ...Appendices App x CONFIDENTIAL PORTEGE R830 Satellite R830 Series Maintenance Manual 960 880 Table I 1 MTBF I 1 ...
Страница 449: ...Appendix B Board Layout Appendices PORTEGE R830 Satellite R830 Series Maintenance Manual 960 880 CONFIDENTIAL B 19 ...
Страница 497: ...Appendices Appendix C Pin Assignments C 48 CONFIDENTIAL PORTEGE R830 Satellite R830 Series Maintenance Manual 960 880 ...
Страница 507: ...Appendices Appendix E Key Layout E 2 CONFIDENTIAL PORTEGE R830 Satellite R830 Series Maintenance Manual 960 880 ...
Страница 509: ...Appendices Appendix F Wiring diagrams F 2 CONFIDENTIAL PORTEGE R830 Satellite R830 Series Maintenance Manual 960 880 ...
Страница 515: ...Appendices Appendix I Reliability I 2 CONFIDENTIAL PORTEGE R830 Satellite R830 Series Maintenance Manual 960 880 ...