Tests and Diagnostics
TECRA A11/S11/P11/Satellite Pro S500 Series Maintenance Manual (960-784) [CONFIDENTIAL]
3-59
3.22.2 Operations
Select
5
and press
Enter
in the DIAGNOSTIC MENU, logs error information into RAM
or onto a floppy disk. The error information is displayed in the following format:
XXXXX ERRORS
CNT TS-NO PASS
STS ADDR
WD
RD HSTS [ERROR STATUS NAME]
001 FDD 02 0000 103 00001
00 00 0000 FDD-WRITE PROTECTED
001 FDD
01
0000
180
00001 00
00 0000 FDD-TIME OUT ERROR
[[1:Next,2:Prev,3:Exit,4:Clear,5:Print,6:FD Log Read,7:FD Log Write]]
2.
The error information displayed on the screen can be manipulated by the following
number keys:
The
1
key scrolls the display to the next page.
The
2
key scrolls the display to the previous page.
The
3
key returns to the Diagnostic Menu.
The
4
key erases all error log information in RAM.
The
5
key outputs the error log information to a printer.
The
6
key reads the log information from a floppy disk.
The
7
key writes the log information to a floppy disk.
3.
In the case of “error retry OK,” a capital “R” will be placed at the beginning of the
error status. However, it is not added to the error count.
Error status name
Error count
Pass count
Error status
Subtest number
Address
Test name
Read data
Write data
HDC status
Содержание Satellite Pro S500
Страница 11: ...1 Hardware Overview 1 2 TECRA A11 S11 P11 Satellite Pro S500 Series Maintenance Manual 960 784 CONFIDENTIAL ...
Страница 109: ...Tests and Diagnostics 3 2 CONFIDENTIAL TECRA A11 S11 P11 Satellite Pro S500 Series Maintenance Manual 960 784 3 ...
Страница 285: ...Chapter 4 Replacement Procedures CONFIDENTIAL ...
Страница 286: ...4 Replacement Procedures 4 ii CONFIDENTIAL TECRA A11 S11 P11 Satellite Pro S500 Series Maintenance Manual 960 784 ...
Страница 290: ...4 Replacement Procedures 4 vi CONFIDENTIAL TECRA A11 S11 P11 Satellite Pro S500 Series Maintenance Manual 960 784 ...