Chapter 2 Troubleshooting Procedures
Satellite L730/Satellite 735/Satellite Pro 730 Maintenance Manual (960-Q08)
35
2.16 Camera Troubleshooting
To check if the computer’s Camera is malfunctioning or not, follow the troubleshooting
procedure below as instructed.
Procedure 1: Camera Execution Check
Procedure 2: Connect Check and Replacement Check
Procedure 1
Camera Execution Check
Open photo/video tool to look if there is an image. If not, go to Procedure 2.
Procedure 2
Connect Check and Replacement Check
The CCD cable is connected to system board. If camera malfunctions, its connection may be
defective or CCD cable and system board may be faulty.
Check 1
Make sure the other side of CCD cable is correctly and firmly inserted to the CN1
in MB. If the problem still occurs, perform Check 2.
Check 2
CCD cable may be faulty. Replace it with a new one. If the problem still occurs,
perform Check 3.
Check 3
Camera may be faulty. Replace it with a new one following the instruction in
Chapter 4.
Check 4
System board may be faulty. Replace it with a new one following the instruction in
Chapter 4.
Содержание Satellite L730 Series
Страница 1: ...Satellite L730 Satellite 735 Satellite Pro 730 Maintenance Manual 960 Q08 Chapter 1 Hardware Overview ...
Страница 22: ...Satellite E300 E305 Maintenance Manual 960 Q08 Chapter 2 Troubleshooting Procedures ...
Страница 63: ...Test Program for Field Satellite L730 Tests and Diagnostics Manual 1 Chapter 3 Diagnostic Programs ...
Страница 133: ...Satellite L730 Satellite 735 Satellite Pro 730 Maintenance Manual 960 Q08 Chapter 4 Replacement Procedures ...
Страница 195: ...Handling the LCD Module Satellite L730 Satellite 735 Satellite Pro 730 Maintenance Manual 960 Q08 4 ...