Chapter 2 Troubleshooting Procedures
Satellite L730/Satellite 735/Satellite Pro 730 Maintenance Manual (960-Q08)
20
Procedure 2 Connector and Replacement Check
The connection of cable and board may be defective. Otherwise, they may be faulty.
Disassemble the computer following the steps described in Chapter 4,
Replacement
Procedures
, and perform the following checks:
Check 1
Make sure the cable is firmly connected to system board.
If the connection is loose, reconnect firmly and repeat Procedure 1. If the problem
still occurs, go to Check 2.
Check 2
Touch Pad or the cable to Touchpad/B may be faulty. Replace it with a new one
following the instructions in Chapter 4,
Replacement Procedures
. If the problem
still occurs, perform Check 4.
Check 3
Touch Pad/B or the cable to MB may be faulty. Replace it with a new one
following the instructions in Chapter 4,
Replacement Procedures
. If the problem
still occurs, perform Check 4.
Check 4
System board may be faulty. Replace it with a new one following the instructions
in Chapter 4,
Replacement Procedures
Содержание Satellite L730 Series
Страница 1: ...Satellite L730 Satellite 735 Satellite Pro 730 Maintenance Manual 960 Q08 Chapter 1 Hardware Overview ...
Страница 22: ...Satellite E300 E305 Maintenance Manual 960 Q08 Chapter 2 Troubleshooting Procedures ...
Страница 63: ...Test Program for Field Satellite L730 Tests and Diagnostics Manual 1 Chapter 3 Diagnostic Programs ...
Страница 133: ...Satellite L730 Satellite 735 Satellite Pro 730 Maintenance Manual 960 Q08 Chapter 4 Replacement Procedures ...
Страница 195: ...Handling the LCD Module Satellite L730 Satellite 735 Satellite Pro 730 Maintenance Manual 960 Q08 4 ...