Toshiba RBC-TBPTs Скачать руководство пользователя страница 5

1. Product Overview

Description

Our  latest  generation  Toshiba 

SMART Touch  Controller  provides  a  modern  compact approach 

to management control technology utilising easy to use Icons and simple intuitive navigation to deliver
sophisticated strategies that provide precise control and data analysis.

The  Toshiba 

SMART Touch  Controller  is  simple  to  install  and  configure  and  offers  three levels of 

operation,  general  user,  building  manager  and  engineering,  all  password 

protectable. The

Toshiba 

SMART Touch controller features a built-in web browser interface,  air conditioning status,

unit enable  and  disable,  time  and  alarm  management  control  and fault indication.

 

Features

§

Built in Web Browser

§

Back-up and Restore

§

Customisable appearance

§

Multi-language preference 

§

Alarm Settings 

§

Unit setup, status and inhibit

§

Programmable time and date events

§

Maximum 64 Indoor Units/Groups and 16 Outdoor systems can be connected 

§

TCB-PCNT30TLE2 Network adaptor required for connection of DI/SDI to provide TCC Link 

 Connection

MAIN FUNCTIONS

FUNCTION

COMMAND INPUT

STATUS OUTPUT

ON/OFF Status

Operation Mode

Auto, Heat, Cool, Dry, Fan Only

Fan Speed

Stop, Auto, Ultra-low, Low, Medium, High

Louver

Horizontal, Vertical, Swing

Set Temperature

18-29

o

C

Room Temperature

Permit/Prohibit of Local Operation

ON/OFF, Mode, Set temp, fan speed, louver

Error Status

Reset

Error Code

Reset

Limits

The device is limited to standard network restrictions applied to the TCC- link network with a maximum indoor unit count of 64 indoor
units.

Chassis material

Aluminium / Steel

Power Supply

230V AC 5VA

Number of Connectable Indoor Units

64

Operating Temperature / Humidity

0 to 40

o

C / 10 to 90%

Storage Temperature

-20 to 60

o

C (no condensation)

Dimensions H X W X D

120 x 200 x 40 mm

Communications Platforms

USB 2.0, RS485, 2-wire Network Bus and Network Connection

Graphic Display

7” Capacitive

 SMART Touch

Screen

Air Conditioner Connection TCC Link

2-wire U3 / U4 communication bus

Digital signals

4x Digital input , 4x relay output

SPECIFICATION

RBC­TBPTS SMART Touch Controller

  Installation & Owners Manual 

5

Содержание RBC-TBPTs

Страница 1: ...SMART Touch Controller RBC TBPTS Installation Manual RBC TBPTS_v1_2015 ...

Страница 2: ...3 2 Digital Outputs 7 2 4 USB 7 2 5 Ethernet 7 2 6 Firmware 7 3 Air Conditioning Address Configuration 8 4 Dimensions 10 5 User Interface 11 5 1 Start Up 11 5 2 SMART Touch View Options 11 5 3 Grid View 11 5 4 List View 12 5 5 Icon 12 5 6 Global Control 13 5 7 Unit Control 13 5 8 Configuration 14 5 9 Network Setting 14 5 10 Time Setting 15 5 11 Group Zone Configuration 15 5 12 Schedule Setup 16 5 ...

Страница 3: ...injury CAUTION BURST HAZARD Open the service valves before the operation otherwise there might be the burst WARNING Moving parts Do not operate unit with grille removed Stop the unit before the servicing CAUTION High temperature parts You might get burned when removing this panel CAUTION Do not touch the alumin um fins of the unit Doing so may result in injury CAUTION BURST HAZARD Open the service...

Страница 4: ...s pipes water pipes lightning rods or ground wires for telephone wires 3 Appliance shall be installed in accordance with national wiring regulations Capacity shortage of power circuit or incomplete installation may cause an electric shock or a fire CAUTION If incorrect incomplete wiring is carried out it will cause an electrical fire or smoke Be sure to install an earth leakage breaker that is not...

Страница 5: ...twork adaptor required for connection of DI SDI to provide TCC Link Connection MAIN FUNCTIONS FUNCTION COMMAND INPUT STATUS OUTPUT ON OFF Status Operation Mode Auto Heat Cool Dry Fan Only Fan Speed Stop Auto Ultra low Low Medium High Louver Horizontal Vertical Swing Set Temperature 18 29 o C Room Temperature Permit Prohibit of Local Operation ON OFF Mode Set temp fan speed louver Error Status Rese...

Страница 6: ...ype 2 core shield wires dedicated cable or equivalent Wire size and max length 1 5 mm 2 500m max min 1 25 mm 2 total length 3 For Power Type H07 RN F or 245IEC66 Wire size 0 75mm 2 50 m max L N 10101 HVAC Ethernet 100 240v 0 4A DO 1 DO 2 DO 3 DO 4 DI 1 DI 2 DI 3 DI 4 COM RS485 Power Supply Digital Out Digital In RS485 HVAC 10 100 Base T Ethernet Outputs Inputs 240v AC to HVAC to Ethernet The SMART...

Страница 7: ...e IP address otherwise enter the address of the appropriate gateway or router Ensure that the correct USB driver has been installed prior to connecting the SMART Touch Controller to a PC 1 Global disable when active turns all units off and inhibits the remote controllers on becoming inactive removes the inhibits from the remote controllers only 2 Global on on becoming active turns all units ON on ...

Страница 8: ...g CbXccf Ob h H 6 CbXccf Ob h H 6 CbXccf Ob h H 6 0 Md h MmghYa CbXccf Ob h MmghYa XXfYgg HI 61 SMART Touch Controller O O O O O O O O N J HN NF HYhkcf_ XUdhYf fYei fYX Zcf gcaY Md h CbXccf ib hg 3 Air Conditioner Address Configuration RBC TBPTS SMART Touch Controller Installation Owners Manual 8 ...

Страница 9: ...its will not be available Units can be grouped within the SMART Touch using the HVAC configuration option The group number is defined as the lowest indoor unit address within the group This becomes the Header address for the group and is the only address within that group that can accept commands Other units within a group are classed as follower units and contain the same status parameter values ...

Страница 10: ...103 136 52 8 10 173 28 163 138 239 3 5 5 Fixing Frame 4 Dimensions 214 10 RBC TBPTS SMART Touch Controller Installation Owners Manual ...

Страница 11: ...w 5 2 SMART Touch View options Home This button always takes you to the home screen Security For later use Network This indicates connection to a LAN Settings This icon takes you to the settings page View Select Icon List Grid Global RBC TBPTS SMART Touch Controller Installation Owners Manual 11 5 User Interface ...

Страница 12: ... up and down to find the required unit Unit operation can be adjusted by selecting a Unit The Icon view provides a visual unit indication This can be scrolled up and down to find the required unit Unit operation can be adjusted by selecting a Unit RBC TBPTS SMART Touch Controller Installation Owners Manual 12 ...

Страница 13: ...ew allows the same settings to be sent to all indoor units The indoor unit settings can be changed by selecting the unit at which point the above will be displayed The unit settings can be updated RBC TBPTS SMART Touch Controller Installation Owners Manual 13 ...

Страница 14: ...n page allows you to access the controller setup options from unit grouping to schedule configuration The network item allows the IP address to be set for the remote access via the Web browser RBC TBPTS SMART Touch Controller Installation Owners Manual 14 ...

Страница 15: ...ption Groups and zones are configured under HVAC Configuration This allows units to be set as individual units or grouped together To create new Zone or Group and select Configure Groups or Configure Zones from the drop down menu RBC TBPTS SMART Touch Controller Installation Owners Manual 15 ...

Страница 16: ...its they turn red Then select create new group or Zone Individual or header units appear Green Follower units appear blue To deselect go to that option and select the units turn red The selected units can then be added to the groups or Zones Select this will create a schedule add a name example First floor day Select the Timer this will add an event To set up a daily schedule select Daily RBC TBPT...

Страница 17: ...o happen Select the item you wish to set by sliding the switch above the item and select the value An event can be modified by selecting the event and changing the required value RBC TBPTS SMART Touch Controller Installation Owners Manual 17 ...

Страница 18: ...create a Week add a name First floor week Select the Calendar this will open the window below To set up a Weekly schedule select Weekly Select the day and you are able to choose the daily schedule to add RBC TBPTS SMART Touch Controller Installation Owners Manual 18 ...

Страница 19: ...ule to and select The screen below will then appear You now have the option to attach the schedule Either a primary schedule for everyday use or a secondary schedule for special days can be selected The Log Viewer provides a record of system events It can be cleared by selecting the x RBC TBPTS SMART Touch Controller Installation Owners Manual 19 ...

Страница 20: ...er units quantity error E20 Other line connected during automatic address E23 Sending error in communication between outdoor units E25 Duplicated follower outdoor address E26 Decrease of No of connected outdoor units E28 Follower outdoor unit error E31 IPDU communication error F01 Indoor TCJ sensor error F02 Indoor TC2 sensor error F03 Indoor TC1 sensor error F04 TD1 sensor error F05 TD2 sensor er...

Страница 21: ...31 IC error P01 Indoor fan motor error P03 Discharge temp TD1 error P04 High pressure switch detection error P05 Phase missing detection Phase order error P07 Heat sink overheat error P10 Indoor overflow error P12 Indoor fan motor error P13 Outdoor liquid back detection error P15 Gas leak detection P17 Discharge temp TD2 error P19 4 way valve inverse error P20 High pressure inverse error P22 Outdo...

Страница 22: ...oshiba ac com 24 Hour Technical Helpline 0870 843 0333 Fault DN Code Apps Android iPhone Web Page toshiba calc co uk fault codes Fault Code Text Service 07624 803 017 technical enquiries toshiba ac com Technical Department AIR CONDITIONING A division of Toshiba Carrier UK Limited Parkfield House Manchester Old Road Middleton Manchester M24 4DY www toshiba aircon co uk Tel 44 0 870 843 0333 Fax 44 ...

Отзывы: