Tolerance of pipe length and Height difference
<RAV-SM2244AT8, SM2804AT8 series>
*
Ensure that the shortest pipe length complies with the following:
Outdoor unit
Allowable pipe length (m)
Total length
• 1 + 2 + 4
• 1 + 2 + 5
• 1 + 3 + 6
• 1 + 3 + 7
Maximum
Branch piping
• 4
• 5
• 6
• 7
Maximum
Branch piping
• 4
+ 2
• 5
+ 2
• 6
+ 3
• 7
+ 3
Maximum
Branch piping
• ( 4 + 2) – ( 5 + 2)
• ( 4 + 2) – ( 6 + 3)
• ( 4 + 2) – ( 7 + 3)
• ( 5 + 2) – ( 6 + 3)
• ( 5 + 2) – ( 7 + 3)
• ( 6 + 3) – ( 7 + 3)
Maximum
SM2244
70
15
20
6
SM2804
70
15
20
6
Outdoor unit
Height difference (m)
Indoor-outdoor H
Indoor-indoor
(
Δ
h)
Indoor unit: Upper
Outdoor unit: Upper
SM2244
30
30
0.5
SM2804
30
30
0.5