4-way Air Discharge Cassette Type
Installation Manual
EN
•
Measures when check code “E18” appears
in the concurrent twin system (one outdoor
unit)
E18…Displayed when incorrect connections
➀
-
➀
,
➁
-
➁
, and
➂
-
➂
are made between indoor
units.
Measures
Reconnect cables correctly between
indoor units.
Set the address again.
1. Push
,
, and TIME
buttons
simultaneously for at least 4 seconds.
2. “
” flashes on the display as shown in
the following figure.
3. Push
button. “
” changes from
flashing to lighting.
4. Push
button. “
” disappears and
“SETTING” flashes. (It takes 5 minutes.)
5. When “SETTING” disappears, re-setting is
completed and the air conditioner enter the
normal operation standby mode.
A
1
2
3
B
1
2
3
A
1
2
3
B
A
1
2
3
B
1
2
3
A
1
2
3
B
Incorrect connection
Indoor unit
Outdoor unit
Remote
controller
Correct connection
Indoor unit
Outdoor unit
Remote
controller
Disconnect the
connection
➂
-
➂
between indoor units.
1
4
3
4
2
34-EN
+00EH99858901-1_01EN_4-way_IM.book Page 34 Tuesday, June 3, 2008 6:30 PM