– 14 –
<Twin type>
∗
: IEC standard
Indoor unit 1
RAV-
SM562BT-E
SM802BT-E
Model
Indoor unit 2
RAV-
SM562BT-E
SM802BT-E
Outdoor unit
RAV-
SP1104AT(Z)(ZG)-E
SP1404AT(Z)(ZG)-E
Cooling capacity
(kW)
10.0
12.5
Heating capacity
(kW)
11.2
14.0
Indoor unit
Power supply
1 phase 230V (220 – 240V) 50Hz
Running current
(A)
13.78 – 12.63
17.76 – 16.28
Power consumption
(kW)
2.94
3.83
Cooling
Power factor
(%)
97
98
EER
3.4
3.26
Electrical
Energy efficiency class
∗
A
A
characteristics
Running current
(A)
12.98 – 11.90
15.82 – 14.50
Power consumption
(kW)
2.77
3.41
Heating
Power factor
(%)
97
98
COP
4.04
4.11
Energy efficiency class
∗
A
A
Fan
Centrifugal
Fan unit
Standard air flow
H/M/L
(m³/min.)
13.0 / 11.9 / 9.8
19.0 / 16.2 / 13.3
Motor
(W)
120
120
Sound pressure level
H/M/L
(dB•A)
40 / 37 / 33
40 / 37 / 34
Sound power level
H/M/L
(dB•A)
55 / 52 / 48
55 / 52 / 49
Outdoor unit
Power supply
1 phase 230V (220 – 240V) 50Hz
Standard length
(m)
7.5
7.5
Min. length
(m)
3
3
Refrigerant
Max. total length
(m)
50
50
Refrigerant charging amount
40g/m (31m to 50m)
pipe
(Charge-less up to 30m)
Height
Outdoor lower
(m)
30
30
difference
Outdoor higher
(m)
30
30
Fan
Propeller fan
Fan unit
Standard air flow volume
(m³/min.)
101
103
Motor
(W)
100 + 100
100 + 100
Gas side
Main
(mm)
15.9
15.9
Connecting
Sub
(mm)
12.7
15.9
pipe
Liquid side
Main
(mm)
9.5
9.5
Sub
(mm)
6.4
9.5
Sound pressure level
Cooling/Heating
(dB•A)
49 / 50
51 / 52
Sound power level
Cooling/Heating
(dB•A)
66 / 67
68 / 69
Revised 2: Jun., 2008
Toshiba SDI / DI tuotteiden jälleenmyyjä pääkaupunkiseudulla on Jäähdytinpalvelu RefGroup Oy.
www.ilmalämpöpumput.com