background image

– 2 –

Ceiling type

Owner’s Manual

EN

Ceiling type

Owner’s Manual

„

Warning indications on the air conditioner unit

Warning indication

Description

WARNING

ELECTRICAL SHOCK HAZARD

Disconnect all remote electric power supplies before servicing.

WARNING

Moving parts. 
Do not operate unit with grille removed. 
Stop the unit before the servicing.

CAUTION

High temperature parts. 
You might get burned when removing this panel.

CAUTION

Do not touch the aluminum fins of the unit. 
Doing so may result in injury.

CAUTION

BURST HAZARD

Open the service valves before the operation, otherwise there might be 

the burst.

WARNING

ELECTRICAL SHOCK HAZARD

Disconnect all remote 
electric power supplies 
before servicing.

WARNING

Moving parts.
Do not operate unit with grille 
removed.
Stop the unit before the servicing.

CAUTION

High temperature parts.
You might get burned 
when removing this panel.

CAUTION

Do not touch the aluminum 
fins of the unit.
Doing so may result in injury.

CAUTION

BURST HAZARD

Open the service valves before 
the operation, otherwise there 
might be the burst.

1

Precautions for Safety

The manufacturer shall not assume any liability for the damage caused by not observing the description of this 
manual.

WARNING

General

• Carefully read Owner’s Manual before starting the air conditioner. There are many important things to keep in mind 

for daily operation.

• Ask for installation to be performed by the dealer or a professional. Only a qualified installer (*1) is able to install an 

air conditioner. If a non-qualified person installs an air conditioner, it may result in problems such as fire, electric 
shock, injury, water leakage, noise and vibration. 

• Do not use any refrigerant different from the one specified for complement or replacement. Otherwise, abnormally 

high pressure may be generated in the refrigeration cycle, which may result in a failure or explosion of the product or 
an injury to your body.

• Places where the operation sound of the outdoor unit may cause a disturbance. (Especially at the boundary line with 

a neighbour, install the air conditioner while considering the noise.)

Transportation and storage

• To transport the air conditioner, wear shoes with protective toe caps, protective gloves, and other protective clothing.
• To transport the air conditioner, do not take hold of the bands around the packing carton. You may injure yourself if 

the bands should break.

• Before stacking the packing cartons for storage or transportation, heed the precautions written on the packing 

cartons. Failure to heed the precautions may cause the stack to collapse.

• The air conditioner must be transported in stable condition. If any part of the product broken, contact your dealer.
• When the air conditioner must be transported by hand, carry it by two or more people.

Installation

• Only a qualified installer(*1) or qualified service person(*1) is allowed to carry out the electrical work of the air 

conditioner. Under no circumstances must this work be done by an unqualified individual since failure to carry out the 
work properly may result in electric shocks and / or electrical leaks.

• After the installation work has been completed, have the installer explain about the circuit breaker positions. In the 

event that trouble has occurred in the air conditioner, set the circuit breaker to the OFF position, and contact a service 
person.

• If the unit is installed in a small room, take appropriate measures to prevent the refrigerant from exceeding the limit 

concentration even if it leaks. Consult the dealer from whom you purchased the air conditioner when you implement 
the measures. Accumulation of highly concentrated refrigerant may cause an oxygen deficiency accident.

• Do not install the air conditioner in a location that may be subject to a risk of expire to a combustible gas. If a 

combustible gas leaks and becomes concentrated around the unit, a fire may occur.

• Use the company-specified products for the separately purchased parts. Use of non-specified products may result in 

fire, electric shock, water leakage or other trouble. Have the installation performed by a professional.

• Confirm that earthing is performed correctly. 

3-EN

4-EN

+00EH99938101_01EN.book  Page 2  Tuesday, April 12, 2011  1:25 PM

Содержание RAV-SM1104CT-E

Страница 1: ...Manual English AIR CONDITIONER SPLIT TYPE Owner s Manual Indoor Unit Model name Ceiling Type RAV SM564CT E RAV SM804CT E RAV SM1104CT E RAV SM1404CT E 00EH99938101_01EN book Page 1 Tuesday April 12 2011 1 25 PM ...

Страница 2: ...relocation and removal has the qualifications pertaining to this refrigerant handling and piping work as stipulated by the local laws and regulations and he or she is a person who has been trained in matters relating to refrigerant handling and piping work on the air conditioners made by Toshiba Carrier Corporation or alternatively he or she has been instructed in such matters by an individual or ...

Страница 3: ...e boundary line with a neighbour install the air conditioner while considering the noise Transportation and storage To transport the air conditioner wear shoes with protective toe caps protective gloves and other protective clothing To transport the air conditioner do not take hold of the bands around the packing carton You may injure yourself if the bands should break Before stacking the packing ...

Страница 4: ...ric shocks or other trouble If the fan grille is damaged do not approach the outdoor unit but set the circuit breaker to the OFF position and contact a qualified service person to have the repairs done Do not set the circuit breaker to the ON position until the repairs are completed If there is a danger of the indoor unit s falling do not approach the indoor unit but set the circuit breaker to the...

Страница 5: ...e In case that cardboard boxes protrude out of pallet when stacking Lay a 10 mm thick plywood over the pallet 11 cartons 2 Part Names Indoor unit Outdoor unit The design varies depending on the outdoor unit The following illustration shows an example Horizontal louver Vertical grille Air discharge The air discharge direction can be changed Air intake grille Air is taken in through here Air filter ...

Страница 6: ... The selected fan speed mode is displayed 11Set temperature display The selected set temperature is displayed 12 Power saving mode display Limits compressor speed capacity to save energy Auto High Med Low 1 6 4 2 3 5 9 15 17 16 11 14 13 12 10 19 20 18 8 7 13 UNIT No display Displays the number of the indoor unit selected Also displays error code of indoor and outdoor units 14 Central control displ...

Страница 7: ...the surrounding of the remote controller can also be sensed For details contact the dealer from which you have purchased the air conditioner 8 6 4 3 2 5 7 10 12 1 9 11 4 Correct Usage When the air conditioner is used for the first time or when the setting is changed follow the steps below Settings are saved in memory and are displayed anytime the unit is turned on by pushing the button Preparation...

Страница 8: ...s available during the 8 C heating operation The 8 C heating operation is cancelled in the following cases When operation is stopped with button When another operation mode is selected with button When temperature setting or operation mode is changed or operation is started stopped by the wireless remote controller or the central control remote controller When this operation mode is used observe p...

Страница 9: ...t position and then push again SWING is displayed and the up down wind direction is automatically selected Display during swinging How to stop swinging 1 Push at a desired position while the louver is swinging When is pushed after that wind direction can be set again from the highest position However even if is pushed while the louver is swinging the louver position is displayed as follows and hig...

Страница 10: ...m current is limited to approximately 75 factory default of the normal mode To adjust the power save settings see To configure the power saving mode settings in Power Saving Mode Even when operation start stop operation mode change or power reset is performed during the power saving mode the power saving mode is retained until the next operation 8 Self Clean Operation Mode This function is provide...

Страница 11: ...at the indoor and outdoor units of the air conditioner in use be cleaned and maintained regularly to ensure efficient operation of the air conditioner When the air conditioner is operated for a long time periodic maintenance once a year is recommended Furthermore regularly check the outdoor unit for rust and scratches and remove them or apply rustproof treatment if necessary As a general rule when...

Страница 12: ... and contracts slightly due to temperature change Various smells from the walls carpet clothes cigarette cosmetics etc adhere to the air conditioner The fan keeps running to self clean operation the heat exchanger during drying The unit does not run Has a blackout occurred Has the circuit breaker blown Has the protective device been activated The operation indicator and on the remote controller ar...

Страница 13: ...ator on the remote controller blink If the protective device is activated Turn off the circuit breaker and perform a checkup Continued running may cause a malfunction Check whether the air filter is installed If not the heat exchanger may be clogged with dust and water leakage may occur During cooling The air intake or discharge of the outdoor unit is clogged Strong wind continuously blows against...

Страница 14: ...anger Do not install the air conditioner near an obstacle air vent lighting equipment etc that disturbs discharge air Turbulent airflow may reduce the performance or disable devices Do not use the air conditioner for special purposes such as preserving food precision instruments or art objects or where breeding animals or growing plants are kept This may degrade the quality of preserved materials ...

Страница 15: ...td Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom Hereby declares that the machinery described below Generic Denomination Air Conditioner Model type RAV SM564CT E RAV SM804CT E RAV SM1104CT E RAV SM1404CT E Commercial name Digital Inverter Series Super Digital Inverter Series Air Conditioner Complies with the provisions of the Machinery Directive Directive 2006 42 E...

Страница 16: ...CORPORATION Address city country 336 Tadehara Fuji shi Shizuoka ken 416 8521 Japan Name of the Importer Distributor in EU Toshiba Carrier UK Ltd Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom 00EH99938101_01EN book Page 33 Tuesday April 12 2011 1 25 PM ...