Operations and Performance

Check before running

• Check whether the earth wire is cut or disconnected.
• Check whether the air filter is installed.
• Turn on the circuit breaker 12 hours or more before 

starting operation.

3 minutes protection function

3-minutes protection function prevents the air 
conditioner from starting for initial 3 minutes after the 
main power switch / circuit breaker is turned on for re-
starting the air conditioner.

Power failure

Power failure during operation will stop the unit 
completely.
• To restart the operation, push the ON / OFF button 

on the remote controller.

• Lightning or a wireless car telephone operating 

nearby may cause the unit to malfunction. Turn off 
the main power switch or circuit breaker and then 
turn them on again. Push the ON / OFF button on the 
remote controller to restart.

Defrosting operation

If the outdoor unit is frosted during the heating 
operation, defrosting starts automatically (for 
approximately 2 to 10 minutes) to maintain the heating 
capacity.
• The fans in both indoor and outdoor units will stop 

during the defrosting operation.

• During the defrosting operation, the defrosted water will 

be drained from the bottom plate of the outdoor unit.

Heating capacity

In the heating operation, the heat is absorbed from the 
outside and brought into the room. This way of heating 
is called heat pump system. When the outside 
temperature is too low, it is recommended to use 
another heating apparatus in combination with the air 
conditioner.

Protective device

• Stops operation when the air-conditioner is 

overloaded.

• If the protective device is activated, the unit stops 

running, and the operation indicator and check 
indicator on the remote controller blink.

If the protective device is activated

• Turn off the circuit breaker and perform a checkup.

 

Continued running may cause a malfunction.

• Check whether the air filter is installed. If not, the 

heat exchanger may be clogged with dust and water 
leakage may occur.

During cooling

• The air intake or discharge of the outdoor unit is 

clogged.

• Strong wind continuously blows against the 

discharge of the outdoor unit.

During heating

• The air filter is clogged with a large amount of dust.
• The air intake or discharge of the indoor unit is 

clogged.

Do not turn off the circuit breaker

• During the air-conditioning season, leave the circuit 

breaker turned on, and use the ON / OFF key on the 
remote controller.

Attention to snowfall and freeze on the outdoor unit

• In snowy areas, the air intake and air discharge of the outdoor unit are often covered with snow or frozen up.

 

If snow or freeze on the outdoor unit is left as it is, it may cause machine failure or poor warming.

• In cold areas, pay attention to the drain hose so that it perfectly drains water without water remaining inside for 

freeze prevention. If water freezes in the drain hose or inside the outdoor unit, it may cause machine failure or 
poor warming.

Air conditioner operating conditions

For proper performance, operate the air conditioner under the following temperature conditions:

If air conditioner is used outside of the above conditions, safety protection may work.

 

Cooling operation

Outdoor temperature

: –15 °C to 43 °C (Dry bulb temp.)

Room temperature

: 21 °C to 32 °C (Dry bulb temp.), 15 °C to 24 °C (Wet bulb temp.)

[CAUTION]

Room relative humidity – less than 80 %. If the air conditioner operates in excess of 

this figure, the surface of the air conditioner may cause dewing.

Heating operation

Outdoor temperature

: –15 °C to 15 °C (Wet bulb temp.)

Room temperature

: 15 °C to 28 °C (Dry bulb temp.)

23-EN

24-EN

+00EH99938101_01EN.book  Page 12  Tuesday, April 12, 2011  1:25 PM

Содержание RAV-SM1104CT-E

Страница 1: ...Manual English AIR CONDITIONER SPLIT TYPE Owner s Manual Indoor Unit Model name Ceiling Type RAV SM564CT E RAV SM804CT E RAV SM1104CT E RAV SM1404CT E 00EH99938101_01EN book Page 1 Tuesday April 12 2011 1 25 PM ...

Страница 2: ...relocation and removal has the qualifications pertaining to this refrigerant handling and piping work as stipulated by the local laws and regulations and he or she is a person who has been trained in matters relating to refrigerant handling and piping work on the air conditioners made by Toshiba Carrier Corporation or alternatively he or she has been instructed in such matters by an individual or ...

Страница 3: ...e boundary line with a neighbour install the air conditioner while considering the noise Transportation and storage To transport the air conditioner wear shoes with protective toe caps protective gloves and other protective clothing To transport the air conditioner do not take hold of the bands around the packing carton You may injure yourself if the bands should break Before stacking the packing ...

Страница 4: ...ric shocks or other trouble If the fan grille is damaged do not approach the outdoor unit but set the circuit breaker to the OFF position and contact a qualified service person to have the repairs done Do not set the circuit breaker to the ON position until the repairs are completed If there is a danger of the indoor unit s falling do not approach the indoor unit but set the circuit breaker to the...

Страница 5: ...e In case that cardboard boxes protrude out of pallet when stacking Lay a 10 mm thick plywood over the pallet 11 cartons 2 Part Names Indoor unit Outdoor unit The design varies depending on the outdoor unit The following illustration shows an example Horizontal louver Vertical grille Air discharge The air discharge direction can be changed Air intake grille Air is taken in through here Air filter ...

Страница 6: ... The selected fan speed mode is displayed 11Set temperature display The selected set temperature is displayed 12 Power saving mode display Limits compressor speed capacity to save energy Auto High Med Low 1 6 4 2 3 5 9 15 17 16 11 14 13 12 10 19 20 18 8 7 13 UNIT No display Displays the number of the indoor unit selected Also displays error code of indoor and outdoor units 14 Central control displ...

Страница 7: ...the surrounding of the remote controller can also be sensed For details contact the dealer from which you have purchased the air conditioner 8 6 4 3 2 5 7 10 12 1 9 11 4 Correct Usage When the air conditioner is used for the first time or when the setting is changed follow the steps below Settings are saved in memory and are displayed anytime the unit is turned on by pushing the button Preparation...

Страница 8: ...s available during the 8 C heating operation The 8 C heating operation is cancelled in the following cases When operation is stopped with button When another operation mode is selected with button When temperature setting or operation mode is changed or operation is started stopped by the wireless remote controller or the central control remote controller When this operation mode is used observe p...

Страница 9: ...t position and then push again SWING is displayed and the up down wind direction is automatically selected Display during swinging How to stop swinging 1 Push at a desired position while the louver is swinging When is pushed after that wind direction can be set again from the highest position However even if is pushed while the louver is swinging the louver position is displayed as follows and hig...

Страница 10: ...m current is limited to approximately 75 factory default of the normal mode To adjust the power save settings see To configure the power saving mode settings in Power Saving Mode Even when operation start stop operation mode change or power reset is performed during the power saving mode the power saving mode is retained until the next operation 8 Self Clean Operation Mode This function is provide...

Страница 11: ...at the indoor and outdoor units of the air conditioner in use be cleaned and maintained regularly to ensure efficient operation of the air conditioner When the air conditioner is operated for a long time periodic maintenance once a year is recommended Furthermore regularly check the outdoor unit for rust and scratches and remove them or apply rustproof treatment if necessary As a general rule when...

Страница 12: ... and contracts slightly due to temperature change Various smells from the walls carpet clothes cigarette cosmetics etc adhere to the air conditioner The fan keeps running to self clean operation the heat exchanger during drying The unit does not run Has a blackout occurred Has the circuit breaker blown Has the protective device been activated The operation indicator and on the remote controller ar...

Страница 13: ...ator on the remote controller blink If the protective device is activated Turn off the circuit breaker and perform a checkup Continued running may cause a malfunction Check whether the air filter is installed If not the heat exchanger may be clogged with dust and water leakage may occur During cooling The air intake or discharge of the outdoor unit is clogged Strong wind continuously blows against...

Страница 14: ...anger Do not install the air conditioner near an obstacle air vent lighting equipment etc that disturbs discharge air Turbulent airflow may reduce the performance or disable devices Do not use the air conditioner for special purposes such as preserving food precision instruments or art objects or where breeding animals or growing plants are kept This may degrade the quality of preserved materials ...

Страница 15: ...td Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom Hereby declares that the machinery described below Generic Denomination Air Conditioner Model type RAV SM564CT E RAV SM804CT E RAV SM1104CT E RAV SM1404CT E Commercial name Digital Inverter Series Super Digital Inverter Series Air Conditioner Complies with the provisions of the Machinery Directive Directive 2006 42 E...

Страница 16: ...CORPORATION Address city country 336 Tadehara Fuji shi Shizuoka ken 416 8521 Japan Name of the Importer Distributor in EU Toshiba Carrier UK Ltd Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom 00EH99938101_01EN book Page 33 Tuesday April 12 2011 1 25 PM ...

Отзывы: