Test run
• Before operating the air conditioner after having completed the
work, check that the electrical control box cover of the indoor unit
and service panel of the outdoor unit are closed, and set the
circuit breaker to the ON position. You may receive an electric
shock if the power is turned on without
fi
rst conducting these
checks.
• If there is any kind of trouble (such as an error display has
appeared, smell of burning, abnormal sounds, the air conditioner
fails to cool or heat or water is leaking) has occurred in the
air conditioner, do not touch the air conditioner yourself but set
the circuit breaker to the OFF position, and contact a quali
fi
ed
service person. Take steps to ensure that the power will not be
turned on (by marking “out of service” near the circuit breaker,
for instance) until quali
fi
ed service person arrives.
Continuing to use the air conditioner in the trouble status may
cause mechanical problems to escalate or result in electric
shocks or other trouble.
• After the work has
fi
nished, use an insulation tester set
(500V Megger) to check the resistance is 1M
Ω
or more between
the charge section and the non-charge metal section
(Earth section). If the resistance value is low, a disaster such as
a leak or electric shock is caused at user’s side.
• Upon completion of the installation work, check for refrigerant
leaks and check the insulation resistance and water drainage.
Then conduct a test run to check that the air conditioner is
operating properly.
Explanations given to user
• Upon completion of the installation work, tell the user where the
circuit breaker is located. If the user does not know where the
circuit breaker is, he or she will not be able to turn it off in the
event that trouble has occurred in the air conditioner.
• If the fan grille is damaged, do not approach the outdoor unit
but set the circuit breaker to the OFF position, and contact
a quali
fi
ed service person to have the repairs done. Do not
set the circuit breaker to the ON position until the repairs are
completed.re completed.
• After the installation work, follow the Owner’s Manual to explain
to the customer how to use and maintain the unit.
Relocation
• Only a quali
fi
ed installer(*1) or quali
fi
ed service person(*1) is
allowed to relocate the air conditioner. It is dangerous for the
air conditioner to be relocated by an unquali
fi
ed individual
since a
fi
re, electric shocks, injury, water leakage, noise and/or
vibration may result.
• When carrying out the pump-down work shut down the
compressor before disconnecting the refrigerant pipe.
Disconnecting the refrigerant pipe with the service valve left
open and the compressor still operating will cause air or other
gas to be sucked in, raising the pressure inside the refrigeration
cycle to an abnormally high level, and possibly resulting in
rupture, injury or other trouble.