Toshiba RAV-HM1101UTP-E Скачать руководство пользователя страница 6

10-EN

9-EN

– 5 –

• When the air conditioner is operated with a combustion 

appliance in the same place, ventilate the room suf

fi

ciently. 

Poor ventilation causes oxygen shortage.

• When the air conditioner is used in a closed room, suf

fi

ciently 

ventilate the room. Poor ventilation causes oxygen shortage.

• Do not expose your body to cool air directly for a long time and 

do not cool yourself excessively.
Doing so may result in deteriorated physical condition and ill 
health.

• Do not insert your 

fi

nger or a stick into the air intake or 

discharge.
Doing so may result injury as the fan is rotating at high speed 
inside the unit.

• Consult the shop where you purchased the air conditioner if air 

conditioning (cooling and heating) is not performed properly 
as a refrigerant leakage may be the cause. Con

fi

rm the repair 

details with a quali

fi

ed service person(*1) when the repair 

includes additional charging of the refrigerant.

• Stop running the air conditioner and turn off the breaker before 

cleaning.
Otherwise, injury may result as the fan is rotating at high speed 
inside the unit

Repairs

• If there is any kind of trouble (such as when an error display 

has appeared, there is a smell of burning, abnormal sounds 
are heard, the air conditioner fails to cool or heat or water is 
leaking) has occurred in the air conditioner, do not touch the 
air conditioner yourself but set the circuit breaker to the OFF 
position, and contact a quali

fi

ed service person. Take steps to 

ensure that the power will not be turned on (by marking “out 
of service” near the circuit breaker, for instance) until quali

fi

ed 

service person arrives. Continuing to use the air conditioner in 
the trouble status may cause mechanical problems to escalate 
or result in electric shocks or other trouble.

• If the fan grille is damaged, do not approach the outdoor unit 

but set the circuit breaker to the OFF position, and contact 
a quali

fi

ed service person to have the repairs done. Do not 

set the circuit breaker to the ON position until the repairs are 
completed.

• If there is a danger of the indoor unit’s falling, do not approach 

the indoor unit but set the circuit breaker to the OFF position, 
and contact a quali

fi

ed installer or a quali

fi

ed service person to 

re

fi

t the unit. Do not set the circuit breaker to the ON position 

until the unit has been re

fi

tted.

• If there is a danger of the outdoor unit’s toppling over, do not 

approach the outdoor unit but set the circuit breaker to the OFF 
position, and contact a quali

fi

ed installer or a quali

fi

ed service 

person to have the improvements or re

fi

tting done. Do not set 

the circuit breaker to the ON position until the improvements or 
re

fi

tting is completed.

• Do not customize the unit. Doing so may result in 

fi

re, electric 

shock or other trouble.

Relocation

• When the air conditioner is to be relocated, do not relocate it 

yourself but contact a quali

fi

ed installer or a quali

fi

ed service 

person. Failure to relocate the air conditioner properly may 
result in electric shocks and/or a 

fi

re.

Содержание RAV-HM1101UTP-E

Страница 1: ... CONDITIONER SPLIT TYPE Owner s Manual Indoor Unit Model name For commercial use English R32 4 way Cassette Type RAV HM561UTP E RAV HM801UTP E RAV HM901UTP E RAV HM1101UTP E RAV HM1401UTP E RAV HM1601UTP E ...

Страница 2: ...uced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory o...

Страница 3: ...alternatively he or she has been instructed in such operations by an individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to these operations The qualified service person who is allowed to do the electrical work involved in installation repair relocation and removal has the qualifications pertaining to this electrical work as stipulated by th...

Страница 4: ... industry or for commercial use by lay persons Transportation and storage To transport the air conditioner wear shoes with protective toe caps protective gloves and other protective clothing To transport the air conditioner do not take hold of the bands around the packing carton You may injure yourself if the bands should break Warning indications on the air conditioner unit Warning indication Des...

Страница 5: ...rthing is performed correctly Operation Before opening the intake grille of the indoor unit or service panel of the outdoor unit set the circuit breaker to the OFF position Failure to set the circuit breaker to the OFF position may result in electric shocks through contact with the interior parts Only a qualified installer 1 or qualified service person 1 is allowed to remove the intake grille of t...

Страница 6: ...ition and contact a qualified service person Take steps to ensure that the power will not be turned on by marking out of service near the circuit breaker for instance until qualified service person arrives Continuing to use the air conditioner in the trouble status may cause mechanical problems to escalate or result in electric shocks or other trouble If the fan grille is damaged do not approach t...

Страница 7: ...unction or water leak from the unit Prevent any liquid from falling into the remote controller Do not spill juice water or any kind of liquid Do not wash the air conditioner Doing so may result in electric shock Check whether the installation base and other equipment have become deteriorated after being used for a long time Leaving them such condition may result in the unit s falling down and caus...

Страница 8: ...e out of pallet when stacking Lay a 10 mm thick plywood over the pallet 2 Part names Indoor unit Projection of air filter Discharge louver of discharge port Change the direction of the air to be discharged according to cool heat mode Suction air port The air in the room is sucked in from this port Earth screw Provided in the electrical control box Knob Knob to open close the suction port Air filte...

Страница 9: ...r central control devices If the central control prohibits using the remote controller will flash when pressing the ON OFF mode or temperature button on the remote controller indicating that these buttons do not work The settings that can be configured on the remote controller will vary depending on the central control mode For details please read the Owner s Manual of the central remote controlle...

Страница 10: ...time then the running mode and its icons change in the following order Auto Dehumidify Heat Dry Cool Fan Dehumidify is not available for concealed duct high static press type If the button is not operated within 30 seconds the running mode selection will end 3 Select the fan speed Switch to the fan speed mode by pressing the menu button The current fan speed icon flickers Press the set button each...

Страница 11: ...itions Setting for fan speed is available during the 8 C heating operation The 8 C heating operation is cancelled in the following cases When operation is stopped with button When another operation mode is selected with button When temperature setting or operation mode is changed or operation is started stopped by the wireless remote controller or the central control remote controller When this op...

Страница 12: ...om or remove the already existing mold and dust inside the indoor unit To cancel the self clean function consult the dealer 6 Maintenance WARNING Cleaning the air filter and other parts of the air filter involves dangerous work in high places so be sure to have a qualified installer or qualified service person to do it Do not attempt it by yourself CAUTION Do not push buttons with wet hands Doing ...

Страница 13: ...itioner When the air conditioner is operated for a long time periodic maintenance once a year is recommended Furthermore regularly check the outdoor unit for rust and scratches and remove them or apply rustproof treatment if necessary As a general rule when an indoor unit is operated for 8 hours or more daily clean the indoor unit and outdoor unit at least once every 3 months Ask a professional fo...

Страница 14: ...ge of the outdoor unit are often covered with snow or frozen up If snow or freeze on the outdoor unit is left as it is it may cause machine failure or poor warming In cold areas pay attention to the drain hose so that it perfectly drains water without water remaining inside for freeze prevention If water freezes in the drain hose or inside the outdoor unit it may cause machine failure or poor warm...

Страница 15: ...ace where sulfureous gas generated such as in a spa Do not install the air conditioner in a vessel or mobile crane Do not install the air conditioner in an acidic or alkaline atmosphere in a hot spring area or near a chemicals factory or in a place subject to combustion emissions Corrosion may be generated on the aluminum fin and copper pipe of the heat exchanger Do not install the air conditioner...

Страница 16: ... becomes invalid if technical or operational modifications are introduced without the manufacturer s consent Declaration of Conformity Manufacturer Toshiba Carrier Thailand Co Ltd 144 9 Moo 5 Bangkadi Industrial Park Tivanon Road Tambol Bangkadi Amphur Muang Pathumthani 12000 Thailand TCF holder TOSHIBA CARRIER UK LTD Porsham Close Belliver Industrial Estate Roborough Plymouth Devon PL6 7DB United...

Страница 17: ...144 9 Moo 5 Bangkadi Industrial Park Tivanon Road Tambol Bangkadi Amphur Muang Pathumthani 12000 Thailand 1115350295 ...

Отзывы: