- 93 -
EN-185
EN-186
Declaration of Conformity
Note:
This declaration becomes invalid if technical or operational modifications are introduced without the
manufacturer’s consent.
Manufacturer:
TOSHIBA CARRIER CORPORATION
336 Tadehara, Fuji-shi, Shizuoka-ken 416-8521 JAPAN
TCF holder:
TOSHIBA CARRIER EUROPE S.A.S
Route de Thil
01120 Montluel FRANCE
Hereby declares that the machinery described below:
Generic Denomination: Air Conditioner
Model/type:
RAV-GP801AT-E, RAV-GP1101AT-E, RAV-GP1401AT-E1
RAV-GP801ATJ-E, RAV-GP1101ATJ-E, RAV-GP1401ATJ-E1
Commercial name:
Super Digital Inverter Series Air Conditioner
Complies with the provisions of the “Machinery” Directive (Directive 2006/42/EC) and the regulations transposing
into national law
Complies with the provisions of the following harmonized standard:
EN 378-2: 2016
Name:
Sato Kazuhisa
Position:
Senior Manager
Quality Assurance & Service Engineering Dept.
Date:
24 June, 2021
Place Issued:
Japan
Warnings on Refrigerant Leakage
Check of concentration limit
The room in which the air conditioner is to be installed requires a design that in the event of
refrigerant gas leaking out, its concentration will not exceed a set limit.
The refrigerant R32 which is used in the air conditioner is safe, without the toxicity or combustibility of ammonia, and
is not restricted by laws to be imposed which protect the ozone layer. However, since it contains more than air, it
poses the risk of suffocation if its concentration should rise excessively. Suffocation from leakage of R32 is almost
non-existent.
If a conditioner system is to be installed in a small room, select a suitable model and installation procedure so that if
the refrigerant accidentally leaks out, its concentration does not reach the limit (and in the event of an emergency,
measures can be made before injury can occur).
In a room where the concentration may exceed the limit, create an opening with adjacent rooms, or install mechanical
ventilation combined with a gas leak detection device.
The concentration is as given below.
Refrigerant Concentration Limit shall be in accordance with local regulations.
Total amount of refrigerant (kg)
≤
Concentration limit (kg/m
3
)
Min. volume of the indoor unit installed room (m
3
)
Содержание RAV-GP1101AT-E
Страница 95: ... 94 MEMO EN 187 EN 188 ...
Страница 96: ...EB99845801 ...