Connecting cable
Connecting cable connect to
terminal block (1, 2, 3,
˙
)
Stripping length of the connecting cable
3
Connecting cable
50 mm
45 mm
10 mm
Earth line
about 20 cm
10 mm
CAUTION
Power supply must input at Outdoor Unit Terminal Block.
Connecting Cable Connection
Wiring Diagram
2
3
1
2
3
L
N
1(L)
L N GND
Indoor
Terminal
Block
Power supply input
Outdoor
Terminal
Block
Chassis
CAUTION
1. The power supply must be same as the rated of air conditioner.
2. Prepare the power source for exclusive use with air conditioner.
3. Circuit breaker must be used for the power supply line of this air conditioner.
4. Be sure to comply power supply and connecting cable for size and wiring method.
5. Every wire must be connected
fi
rmly.
6. Perform wiring works so as to allow a general wiring capacity.
7. Wrong wiring connection may cause some electrical part burn out.
8. Incorrect or incomplete wiring is carried out, it will cause an ignition or smoke.