10
ELECTRICAL WORKS
ELECTRICAL WORKS
Model
RAS-M10PKVPG-E
RAS-M13PKVPG-E
RAS-M16PKVPG-E
Power source
50Hz, 220 – 240 V Single phase
Maximum running current
*1
*1
*1
Circuit breaker rating
*1
*1
*1
Power supply cable
−
Connecting cable
*1
*1: Refer to the installation manual of the outdoor unit to be combined.
Wiring of the cable can be carried out without removing the main panel.
1. Remove the front panel.
Pull and lift up front panel until it stops, move arms on left and right side
to outward direction then pull toward you to remove front panel.
w
Beware front panel fall down that may cause of injure or part damage.
Arm
Arm
2. Remove the terminal cover and cord clamp.
3. Insert the cable (according to the local cords) into the pipe hole on the
wall.
4. Take out the cable protrudes about 20 cm from the front.
5. Insert the cable fully into the terminal block and secure it tightly with
screws.
6. Tightening torque : 1.2 N·m (0.12 kgf·m)
7. Secure the cable with the cord clamp.
8. Fix the terminal cover and attach front panel to the indoor unit.
Cable
about 20 cm
Front panel
Terminals block
Main panel
Terminal cover
Wiring Connection
Indoor unit
Carry out attaching in the reverse order to removal.
Keep front panel horizontally and put both arms into guides.
Make sure both arms are inserted completely.
If the gap between main panel and front panel isn’t even, remove and attach
again.
How to attach the front panel
• Be sure to refer to the wiring system diagram labeled inside the main
panel.
• Check local electrical cords and also any speci
fi
c wiring instructions or
limitations.
CAUTION
Guide
Arm
Main panel
Front panel