– 24 –
6. SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
RAS-B16EKVP-E, RAS-B13EKVP-E, RAS-B10EKVP-E
RAS-M16EKCVP-E, RAS-M13EKCVP-E, RAS-M10EKCVP-E
No.
1
2
3
4
Parts name
Fan motor (for indoor)
Room temp. sensor
(TA-sensor)
Heat exchanger temp. sensor
(TC-sensor)
Louver motor
Type
MF-280-30-5
( – )
( – )
MP24GA
Specifications
DC280–340V, 30W
10k
Ω
at 25°C
10k
Ω
at 25°C
Output (Rated) 1W, 16poles, 1phase DC12V