No.
Part name
P
rocedure
s
Remarks
Fan motor
Hexagon screw driver
Vertical louver
Cross flow fan
Fan motor
Screws
Motor band
5
1)
Follow the procedure item
3 and 4
.
2)
Loosen the set screw of the cross flow fan.
3)
Remove 2 fixing screws of the motor band
.
4)
Pull the motor band and the fan motor
outward.
3.5 mm
Cross flow fan
Set screw
Fan motor
Body back
Horizontal louver
6
1) Remove shaft of the horizontal louver
from the back body. (First remove 2 the
center shafts then remove the other shafts.)
Horizontal louver
Drain pan
<To re-installation>
- Check the type name of fan mo
tor.
- Keep connector position and arrange fan
motor wi
res
follow figure.
For SJM-240-25
(45°)
Fan motor
connector
(45°)
Fan motor
connector
For SJM-240-35
Fan motor wires
Fan motor wires