– 57 –
[In starting and in stability]
FAN AUTO
FAN Manual
In starting
• Until 12 minutes passed after operation start
• When 12 to 25 minutes passed after operation start
and room temp. is 3°C or lower than set temp.
• Room temp. < Set temp. –4°C
In stability
• When 12 to 25 minutes passed after operation start and
room temp. is higher than (set temp. –3°C)
• When 25 minutes or more passed after operation start
• Room temp.
≥
Set temp. –3.5°C
Fan speed level
WF
WE
UH
WD
H
WC
M+
WB
WA
M+
W9
W8
L+
W7
L
W6
L–
W5
UL
W4
W3
SUL
W2
W1
RAS-M10PKVP-E
RAS-M10PKVP-ND
Fan speed Air flow rate
(rpm)
(m
3
/h)
1140
640
1140
640
1070
590
980
530
900
470
850
430
810
400
710
330
710
330
650
290
650
290
650
290
650
290
560
220
420
120
RAS-M13PKVP-E
RAS-M13PKVP-ND
Fan speed Air flow rate
(rpm)
(m
3
/h)
1200
690
1200
690
1100
610
1010
550
930
490
850
430
810
400
710
330
710
330
650
290
650
290
650
290
650
290
560
220
420
120
RAS-M16PKVP-E
RAS-M16PKVP-ND
Fan speed Air flow rate
(rpm)
(m
3
/h)
1280
750
1280
750
1180
670
1090
610
980
530
900
470
880
450
780
380
710
330
700
320
650
290
650
290
650
290
560
220
420
120
RAS-M18PKVP-E
RAS-M18PKVP-ND
Fan speed Air flow rate
(rpm)
(m
3
/h)
1390
805
1390
805
1290
730
1180
655
1070
575
980
510
950
490
850
420
850
420
700
310
650
275
650
275
650
275
560
210
420
110
Item
2. Indoor fan motor control
Operation flow and applicable data, etc.
Description
(Table 2) Indoor fan air flow rate (Heating)
Содержание RAS-3M26GAV-E1
Страница 116: ... 116 MCC 1438 ...
Страница 117: ... 117 MCC 818 ...